XT302C DELUXE PROGRAMMABLE HEAT-COOL THERMOSTAT
2. Press Day until the current day displays.
Set Current
Run
Wake
Leave
Return
Program
Day/Time
Day
Time
Set Program
Heat/Cool
Hold Temp
Day
Filter
System
Settings
Daylight
Copy
Time
NOTE: Sun=Sunday, Mon=Monday, Tue=Tuesday,
Wed=Wednesday, Thu=Thursday, Fri=Friday,
Sat=Saturday.
3. Press Time
or Time
Time
Set Current
Run
Wake
Leave
Program
Day/Time
Time
Set Program
Heat/Cool
Hold Temp
Day
Filter
System
Settings
Daylight
Copy
Time
NOTE: Tapping the Set Current Day/Time will change the
time in one hour increments.
NOTE: If the current time is Daylight Savings Time, press
Daylight Time until DST displays.
Daylight
Run
Set Current
Wake
Leave
Return
Program
Day/Time
Time
Set Program
Time
Heat/Cool
Hold Temp
Day
Settings
Filter
System
Daylight
Copy
Time
4.
Press Run Program.
Run
Run
Set Current
Wake
Leave
Program
Day/Time
Program
Time
Set Program
Heat/Cool
Hold Temp
Day
Filter
Settings
Daylight
Copy
Time
INSTALLER SELF-TEST
Use the Installer Self-Test to check the thermostat operation.
Refer to Table 4 for a list of the available self-tests.
CAUTION
Equipment Damage Hazard.
Equipment damage can occur if the compressor
is cycled too quickly.
The minimum off time is deactivated during the
Installer Self-Test.
Perform the test so that the compressor is cycled
slowly.
Pub. No. 18-HD25D7-5
69-1213—1 (T8624)
Set Day/Time
PM
Tue
Sleep
Fan
M12952
until the current time displays.
Set Day/Time
AM
Tue
Return
Sleep
Fan
M12953
Set Day/Time
AM
Tue
Sleep
DST
Fan
M12954
AM
Room
Tue
Return
Sleep
Wake
System
DST
Fan
System
Fan
Heat
M12955
To start the self-test:
Press and hold the Increase
same time until all display segments and the number 10
appears (all displays segments appear for approximately
three seconds before the test number displays). See
Figs. 12 and 13.
Table 4. Tests Available In The Installer Self-Test.
Test
Number
10
Heating Equipment
30
Cooling Equipment
40
Fan Equipment
50
Comfort-R Terminals (H-H)
60
Keyboard Operation
70
Device Information
Set Program
Hold for
Em Ht
Aux Ht
Mon
TueWedThuFriSatSun
Wake
LeaveReturnSleep
System
Em Heat
Off
Fig. 12. Display of all the segments of the LCD.
Auto
Fig. 13. Display of test number.
Refer to Table 5 for the directions and results of the specific tests.
NOTE: Press Time
to go back to the previous test. Press Run Program to
exit the self-test. This mode times out 5 minutes after
the last key press.
NOTE: Press Time
to advance to the next test.
NOTE: To exit, press Time
8
and Decrease
Self-Test Description
Temporary Setting Enrg
Start Time
Set Day/Time
AM
PM
Heat
Cool
In
Recovery
Auto
Fan
DST
Cool
Auto
Wait
TEST NUMBER
to advance to the next test and Time
to return to the previous test or Time
or Time
then Run Program.
keys at the
Sav
Room
Outdoor
Repl Batt
On
Auto
M17111