  • Page 1 PLEASE READ AND SAVE ALL INSTRUCTIONS! LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS! POR FAVOR LEA Y GUARDE TODAS! AOS 7133 AOS 7135...
  • Page 3: Instructions D'utilisation

    Instructions for use (5 – 18) Instructions d‘utilisation (19 – 2) Instrucciones para el uso ( – 47)
  • Page 5 Instructions for use...
  • Page 6: Important Safety Instructions

    PLEASE READ AND SAVE ALL THESE INSTRUCTIONS! Important safety instructions • Do not touch the water in the base during operation • The use of water additives, such as ethereal/essential • Prior to using the appliance, read through the in­ because of high frequency vibrations in the water. oils, fragrances, eucalyptus, water conditioners etc., structions for complete use and retain in a safe place • Do not run power cords under carpets, and do not co­ damages the tank material and as a consequence for later reference. ver with throw rugs. Arrange cord so that it will not be the whole unit. Any use of such additives will void the • WARNING – Only use the Ultrasonic indoors and within tripped over. manufacturer’s warranty. the specified technical data. Improper use can be • Never pull the plug from the outlet by the cable or with • Remark: Neither humans nor animals can hear the high hazardous for the health and lead to critical injury. wet hands. frequency vibrations. • Connect the unit only to alternating current with • Do not use the appliance where combustible gases or voltage according to the rating label.
  • Page 8: General Information

    Foreword Unpacking Congratulations on choosing the Ultrasonic AIR­O­SWISS • Carefully remove the humidifier from the box. Place your 7133 / AIR­O­SWISS 7135! hands underneath the product to pull it out of the box (10). Did you know that dry room air: • Warning: Do not take the unit out of the box by pulling • Causes the membranes in your respiratory system to up on the tank handle ­ base may fall and will be dry out, and also causes chapped lips and stinging damaged (11). eyes? • Warning: The mist outlet is packed in a red bag inside • Encourages infections and illnesses of respiratory the box insert. Make sure that you remove the mist system? outlet from the packaging (12). • Causes weariness, tiredness and poor concentration? • Remove the plastic bag from the humidifier. • Stresses household pets and house plants? • Observe the information given on the rating plate about • Encourages the formation of dust and the electrostatic the voltage. charging of textiles made of synthetic fibers, carpets • Use the original packaging for storing the appliance if and plastic flooring? you do not use the humidifier all year round.
  • Page 9: Description Of The Appliance

    Description of the appliance Setting up Finding the ideal location for your unit • Do not place the humidifier directly next to a heating Mist outlet (rotating) element or on a floor with floor heating. The moisture of the mist can damage the floor surface (6) (see Sa­ fety Instructions). • The unit should be placed in an elevated position (7), e.g. on a table, chest, etc. Evaporation chamber • The mist outlet must not be pointed directly at plants or other objects (13). Keep distance of at least 20 inches (50cm). Water tank • Soak the demineralization cartridge in a water bath 24 hours before using it (14). The resin has to absorb water to reach high performance. If it is soaked in the tank, make sure to exchange the water and empty the Demineralization cartridge water from the base before using the humidifier. • On average the demineralization cartridge should Water tank cap be replaced every 2 – 3 months depending on your water hardness. Some areas may need to replace the Brush cartridge sooner, some may last longer. The cartridge must be exchanged at the latest after 6 months or the Water base unit does not reach its full performance anymore. See Control panel «Replacement of the demineralization cartridge».
  • Page 10: Filling The Tank

    Filling the tank Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! Do not operate the humidifier when the water tank is empty! When the water reaches the minimum level, the unit switches off the nebulizer function automatically. The red light comes on indicating tank is empty. • Make sure that no foreign objects are in the water tank. • Take off the water tank cap to fill the tank with water (15). Fill the tank with clean, cold water from the tap (16). Close the cap of the water tank securely, place the water tank onto the base (17). The water is now running from the tank into the base. • Do not pour water into the mist outlet of the appliance (18). • Insert the plug into the socket and switch on the 7133 appliance using the on/off switch (19). The green light comes on. Use of additives Water additives (ethereal/essential oils, fragrances, eucalyptus, water conditioners etc.) must not be used! 7135 Even a small amount can cause cracks in the material.
  • Page 11 Operation of the 71 model Operation of the 715 model E) Setting the timer With button E you can set the humidifier to operate for between 1 and 9 hours, or on continuous operation. When selecting the desired time, «TIME» will be shown on the display. The display will automatically show the current humidity value after a few seconds.
  • Page 12: Cleaning & Maintenance

    Cleaning/Maintenance Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! 7133 • Switch off the appliance and unplug it from the socket before cleaning it (20). • Clean the water tank and the base regularly. Use water only, no detergents (21). • Use AIR­O­SWISS EZCal custom cleaning and descaling agent to remove deposits from the membrane regularly (22 ­ 23). There is a sample of EZCal included in the 7135 packaging of your humidifier. Instructions for using are on the packet. Only use 1 packet for 32 oz of water. Do not change te ratio. Do NOT run the unit when using EZCal. This can cause damage to the product and voids the warranty. Thoroughly rinse the base with potable water after using EZCal and make sure no EZCal resi­ dues remain in the base. • Do not submerge base in water (24)! • The cleaning indicator still appears on the display after cleaning. To reset it hold down the ON/OFF button until the clean light stops flashing. Caution – risk of electric shock and damage of the product! • Make sure main body is never submerged into water (24)!
  • Page 13 Replacement of the demineralization cartridge Always unplug the unit before removing the water tank. Do not touch the water in the base during operation! The water tank is equipped with a demineralization cart­ ridge. This cartridge has to be replaced every 2 – 3 months. If the water is very hard, it may be necessary to replace the cartridge earlier. White dust around the device is a sure sign that the cartridge needs replacing. Please note white dust is not harmful. If white residue still forms around the device after a new cartridge has been inserted, please make sure that the water you are using is untreated. If the water flows through a decalcification system – such as an ion exchanger ­ (sodium is added to remove calcium) in the building before it is used in the humidifier, salt can precipitate as white dust around the device. The demineralization cartridge and or the granules must be exchanged at the latest after 6 months or...
  • Page 14 Water quality maintenance • Screw the cartridge on the water tank cap (34). • Close tank cap well, place the tank on the lower part An Ionic Silver Stick (36) keeps the water free of micro­ ® and insert mist outlet (35). bial growth. This is an optional accessory. However, we as • Soak the demineralization cartridge in a water bath 24 the manufacturer highly recommend to use it in order to hours before using it. The resin has to absorb water keep the unit safe and free of microbial growth. The anti­ to reach high performance. If it is soaked in the tank, microbial action of silver is used. The Ionic Silver Stick ® make sure to exchange the water and empty the water (ISS) releases silver ions in the water over a long period from the base before using the humidifier.
  • Page 15: Technical Data

    Storing the appliance for extended periods Technical data Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its original box, Electrical voltage 120 V / 60 Hz in a dry place away from high temperatures. Power consumption up to 45 W / (140W*) Legal notice Humidity output up to 3.5 gallons / 24 h* The humidifier is cUL­listed. Suitable for rooms up to 650 sq ft / 60 m Subject to technical change. The instructions for use are Dimensions (LxWxH) 15 x 8.7 x 13.8 in protected by copyright © PLASTON AG. 38 x 22 x 35 cm Accessories Weight (empty) 7.7 lbs / 3.5 kg Contact your local retailer or check our website www.airos­ Accessories Demineralization cartridge wiss.net for reorder information.
  • Page 16 General Humidifier Questions A. The moisture level within the outside air is not high Q. There is no fill-line on the water tank, how far may I fill it up? enough to humidify a room. The colder the air the less Q. Why isn’t there enough moisture in my room? moisture it is capable to hold, and the more the air is A. There is no fill line on the water tank, and it may be A. How often do you run the unit? If the unit is only run at heated up the percentage of relative humidity is lower. filled all the way to the top. night, then during the day the moisture level will drop if Relative humidity means the amount of water vapor in moisture is not constantly added to the air. the air, compared to the amount the air could hold if it Q. What is the purpose of the demineralization cart- ridge (DMC)? was totally saturated. The difference is higher between...
  • Page 17 Q. The directions tell me not to place the unit directly mineral build up. If soft water is used decalcifying the the lower is the percentage of relative humidity (=the on the floor, why do I have to elevate the unit? unit every 4 weeks with EZ Cal is suggested. If hard amount of water vapor in the air, compared to the A. The idea with this unit is to allow one to force more water is used the unit should be decalcified every 2 amount the air could hold if it was totally saturated) humidity into the air than is needed. Because of this, weeks. Do not forget to reset the clean light after reset­ • position of the unit ­ if it is placed close to a door, win­ the carpeting or wood floor surrounding the unit may ting the unit. dow or air vent. This increases the air circulation. become damp. If the unit is placed at least 3 feet off Q. R eset cleaning light (model 715/7142) Q. Tank is leaking the floor, the mist will have the opportunity to evapo­...
  • Page 18 Accessories for 24 hours, dry granules take even longer for water to filter through the cartridge and into the base. Next, please remove a tablespoon of granules from the cart­ Q: Do I need to keep any parts before I replace the demineralization cartridge? ridge, and throw them away. When there are too many granules in the cartridge it does not allow water to flow A: Yes, always keep the water tank cap (this is the piece from the tank to the base. that attaches the demineralization cartridge to the water tank). Q: Water tank cap is too tight to unscrew A: This could be a cause of the air pressure within the Q: Ionic Silver Stick (water treatment) replacement ®...
  • Page 19 Please check our website www.airoswiss.net for further information. AIR­O­SWISS is a brand name of PLASTON AG, Switzerland.