JGS650SEF
31 1/4"
GE
30" Slide-In Gas Range
®
cooktop edge to edge
Dimensions and Installation Information (in inches)
3 1/4"
Note: Door handle protrudes 3" from door face. Cabinets and
drawers on adjacent 45° and 90° walls should be placed to
avoid interference with the handle.
Note: Cabinets installed adjacent to slide-in ranges must
have an adhesion spec of at least 194° temperature rating.
Installation Information: Before installing, consult
installation instructions packed with product for
current dimensional data.
26 7/8"
w/o handle
31 1/4"
29 3/8"
cooktop edge to edge
w/ handle
47 5/8"
3 1/4"
26 7/8"
w/o handle
29 3/8"
w/ handle
47 5/8"
SINGLE OVEN SLIDE-IN GAS RANGE
31 1/4"
cooktop edge to edge
3 1/4"
SINGLE OVEN SLIDE-IN GAS RANGE
26 7/8"
w/o handle
29 3/8"
w/ handle
30"
47 5/8"
Minimum to
cabinets on
either side
of the range.
6"
Minimum
Minimum
18"
clearance
to left wall
To cabinets
30"
below
0"
cooktop and
at the range
back
Minimum to
cabinets on
either side
For answers to your Monogram
of the range.
appliance questions, visit our website at
geappliances.com or call GE Answer Center
6"
service, 800.626.2000.
Minimum
18"
clearance
to left wall
SINGLE OVEN SLIDE-IN GAS RANGE
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
Recommended area for 120V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
30"
GAS PIPE AND ELECTRICAL
connection of pipe stub
and shut-off valve.
OUTLET LOCATIONS
Minimum to
cabinets on
Recommended area for 120V
either side
30"
of the range.
outlet on rear wall and area for
30"
through-the-wall conection of
30"
pipe stub and shut-off valve.
6"
Minimum
30"
Minimum
18"
3"
clearance
Minimum
to left wall
clearance to
right wall
To cabinets
below
0"
Recommended area
cooktop and
for through-the-floor
at the range
connection of pipe stub
36"
back
and shut-off valve.
®
or GE
®
30"
®
30"
3"
Minimum
Minimum
clearance to
right wall
30"
GAS PIPE AND ELECTRICAL
4 1/2"
OUTLET LOCATIONS
5"
4"
8"
Recommended area for 120V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
14 1/2"
9"
2"
Recommended area
30"
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
Maximum
depth for
Maximum
4"
cabinets above
8"
depth for
countertops
cabinets above
countertops
3"
Minimum
clearance to
13"
right wall
14 1/2"
9"
2"
Front edge of
the range side
panel forward
Front edge of
from cabinet
36"
the range side
panel forward
from cabinet
0"
To cabinets below cooktop
and at the range back
* ADA qualified based
All GE ranges are equipped with
*
Maximum
on Uniform Federal
an Anti-Tip device. The installation
Accessibility Standards
of this device is an important,
depth for
required step in the installation
cabinets above
of the range.
countertops
Specification Revised 7/13
13"
30"
4 1/2"
24"
24"
35" to 36 1/2"
5"
floor to counter
4"
8"
14 1/2"
9"
3"
3"
2"
24"
5"
35" to 36 1/2"
floor to counter
13"
3"
0"
To cabinets below cooktop
and at the range back
Listed by
Underwriters
Laboratories
R
330238
35" to 36
floor to cou
Need help?