Junction box
location
PK7500SF
Profile
Series 27" Built-In Double Convection Wall Oven
™
44" to
Dimensions and Installation Information (in inches)
bottom of
junction box
Most 30" Wall Cabinets can be used with this unit.
Note: These ovens are not approved for
stackable installations. Cabinets installed
adjacent to wall ovens must have an adhesion
spec of at least a 194°F temperature rating.
F
Door handle protrudes 3" from door face. Cabinets
and drawers on adjacent 45° and 90° walls should
Conduit
be placed to avoid interference with the handle.
40"
Electric wall ovens are not approved for
installation with a plug and receptacle. They
must be hard wired in accordance with
E
installation instructions.
Installation Information: Before installing, consult
installation instructions packed with product for
22"
current dimensional data.
Side-by-side installations rerquire at least 2"
between cutouts.
D
KW Rating
240V
7.2
208V
5.4
C L
Breaker Size
2 x 4 or
equivalent runners
240V
30 Amps
level with bottom of cutout
and flush with sides of cutout
208V
30 Amps
or solid bottom floor.
A
B
8-3/4"
MAX.
Cutout width
Cutout depth
23-1/2" MIN
25-1/4" MAX.
Junction box
location
C
B
44" to
bottom of
junction box
27''
Cabinet
A – Overlap of oven at top of cutout
B – Overlap of oven over side of edges of cutout
Cabinet
A – Overlap of oven at top of cutout
C – Overlap of oven at bottom of cutout
B – Overlap of oven over side of edges of cutout
Oven
C – Overlap of oven at bottom of cutout
Oven
D – Overall depth with handle
D – Overall depth with handle
E – Overall height with trim
E – Overall height with trim
F – Overall width
F – Overall width
For answers to your Monogram
questions, visit our website at geappliances.com
or call GE Answer Center
Cutout height
49-11/16" MIN.
50-1/8" MAX.
25" MIN.
A
Recommended
minimum
Cutout height
cutout location
49-11/16" MIN.
50-1/8" MAX.
from the floor
13-1/4"
C
Recommended
minimum
cutout location
from the floor
13-1/4"
27''
PK7500
27"
PK7500
JK5500
1"
JK3500
1"
27"
1"
1"
1"
1"
26-23/32"
26-23/32"
52-1/8"
52-1/8"
26-23/32"
26-23/32"
®
or GE appliance
®
service, 800.626.2000.
F
F
Conduit
E
22"
23" minimum
door opening
allowance
23" minimum
D
door opening
allowance
C L
2 x 4 or
equivalent runners
level with bottom of cutout
and flush with sides of cutout
or solid bottom floor.
C L
Suitable
bracing
(must support 375 lbs.)
to support
runners
Suitable
bracing
(must support 375 lbs.)
to support
runners
8-3/4"
MAX.
Cutout depth
23-1/2" MIN
Junction box
Conduit
location
40"
40"
44" to
bottom of
junction box
E
22"
D
2 x 4 or
equivalent runners
level with bottom of cutout
and flush with sides of cutout
or solid bottom floor.
Listed by
Underwriters
Laboratories
Specification Created 2/13
220369
B
Ca
A
B
C
Ov
D
E
F
Need help?
Do you have a question about the Profile PK7500SFSS and is the answer not in the manual?