Download Print this page

Rane DC 24 Datasheet page 2

Dynamic controller
Hide thumbs Also See for DC 24:

Advertisement

DC 24
DYNAMIC CONTROLLER
Parameter
Compressor
..........Threshold Range
..........Ratio Range
Expander / Gate
..........Threshold Range
..........Ratio Range
Limiter
..........Threshold Range
Crossover
..........Type
..........Range
Inputs: Type
..........Connectors
..........Impedance
..........Maximum Level
Outputs: Type
..........Connectors
..........Impedance
..........Maximum Level
Overall Gain Range
RFI Filters
Passive Bypass Switch
LED Thresholds: Overload
..........Signal Present
Frequency Response
THD+Noise
IM Distortion (SMPTE)
Signal-to-Noise Ratio
Unit: Agency Listing
..........120 VAC model
..........230 VAC model
Power Supply: Agency Listing
..........120 VAC model
..........230 VAC model
..........100 VAC model
Power Supply Requirement
Maximum Current
Unit: Construction
..........Size
..........Weight
Shipping: Size
..........Weight
Note 1: 0 dBu=0.775 Vrms
Note 2: Unless otherwise stated, all measurements made with Thresholds set at maximum, Ratios set at minimum.
Data Sheet-2
Specification
-50 to +20
1:1 to 10:1
-50 to +10
1:1 to 20:1
-20 to +20
Linkwitz-Riley 4th-order
70 Hz to 7 kHz
Active Balanced / Unbalanced
XLR & + ¼" TRS
20k
+20
Active Balanced
XLR & + ¼" TRS
100
+26
+20
-12 to +12
Yes
Yes
+22
-40
20 Hz to 20 kHz
0.05
0.1
108
92
Class 2 Equipment
UL & CSA
CE-EMC
CE-Safety
Rane model RS 1
UL
CSA
CE-EMC
CE-Safety
Built to JIS
18 VAC w/center tap
600
All Steel
1.75"H x 19"W x 5.3"D (1U)
5 lb
4.5" x 20.3" x 13.75"
9 lb
Limit
Units
Conditions/Comments
5
dB
10
%
5
dB
10
%
2
dB
24 dB per octave slopes
5
%
41-detent continuously variable pot
1%
Ω
1
dBu
1%
Ω
Each output
1
dBu
2 kΩ or greater
1
dBu
600 Ω or greater
±1
dB
Center detent unity gain
1
dBu
Output or any internal level
3
dBu
Input Level
+0/-.5
dB
.01
%
+4 dBu, 1 kHz
.01
%
60 Hz / 7 kHz, 4:1, +4 dBu
2
dB
Unity Gain re +20 dBu, 20 kHz BW
2
dB
Unity Gain re +4 dBu, 20 kHz BW
National Electrical Code
Exempt Class 2 equipment
EMC directive 89/336/EEC
Exempt per art. 1, LVD 73/23/EEC
Class 2 Equipment
File no. E88261
File no. LR58948
EMC directive 89/336/EEC
LV directive 73/23/EEC
Japan only
0.1
Vrms
mA
RMS current from remote supply
(4.4 cm x 48.3 cm x 13.5 cm)
(2.3 kg)
(11.5 cm x 52 cm x 35 cm)
(4.1 kg)

Advertisement

loading

Related Products for Rane DC 24