Forced Unpair - NEC Storage Manager IS015-9E User Manual

Data replication
Table of Contents

Advertisement

Chapter 3 Replication Management
3
.
3
.
9
F
3
.
3
.
9
F
3
.
3
.
9
When a failure occurs in the disk array of MV or RV, monitoring is suspended and the normal Cancel
Pair may not be performed. In such a case, you can use Forced Unpair to unpair the pairs for MV and
RV separately.
[Operation Procedure]
Before performing Forced Unpair, you must separate MV and RV with Separate or Forced Separate.
Do one of the following to display the Forced Unpair screen.
• Select a volume in the Replication Information screen, click [Operation] on the menu bar of the
Replication screen, point to [Forced Operation], and then select [Forced Unpair].
• Right-click in the Replication Information screen, point to [Forced Operation], and then select

[Forced Unpair].

Figure 3-38 shows an example of the Forced Unpair screen.
(i)
(ii)
From the list, select a pair for which you want to perform the operation, and then click the [Execute]
button.
You can select multiple executable pairs and execute them in a batch.
Unexecutable pairs cannot be selected.