Page 1
Western Digital SCSI Hard Drives WD Enterprise WDE2170 WDE4360 CCC: A9 Technical Reference Manual...
Page 2
Information furnished by Western Digital Corporation is believed to be accurate and reliable. No license is granted by implication or otherwise under any patent or patent rights of Western Digital Corporation. Western Digital Corporation reserves the right to change specifications at any time without notice.
Page 3
WD Enterprise WDE2170/WDE4360 (CCC: A9) Technical Reference Manual 4079-001045 Rev. B RELEASED 04-08-97...
WD Enterprise WDE2170/WDE4360 Table of Contents ABLE OF ABLE OF ONTENTS ONTENTS ................1 1. D ESCRIPTION AND EATURES 1.1. General Description......................... 1 1.2. Advanced Features ........................2 1.3. Options ........................... 3 2. S ....................4 PECIFICATIONS 2.1. Performance Specifications...................... 4 2.2.
Page 6
Table of Contents WD Enterprise WDE2170/WDE4360 3.15. LED Support ......................... 23 3.16. Option Block Functions ......................24 3.17. Error Recovery Operations ....................25 3.18. Self-Monitoring, Analysis, and Reporting Technology (S.M.A.R.T.) ........25 3.19. Hot Plug/Unplug Support ...................... 26 .............. 27 4.
The WDE2170 and WDE4360 drives feature formatted capacities of 2.1 and 4.3 gigabytes with media data transfer rates up to 140 Mbits per second. These drives are SCSI-3 SPI compliant and support Ultra Fast and Ultra Fast Wide host transfer rates of up to 40 MB/s.
These advanced product features are further defined in section 3. In certain cases we refer you to other documents for additional detail. To obtain a document, contact your local Western Digital sales office, authorized Western Digital reseller, or access the Western Digital web page at www.wdc.com RELEASED 04-08-97 4079-001045 Rev.
The drive is shipped in bulk packaging to provide maximum protection against damage during transit. Units shipped individually require additional protection as provided by the single-unit shipping pack. Contact your local Western Digital sales office for ordering information. Differential SCSI The WD Enterprise drive provides, as an option, differential SCSI drivers/receivers on the 68-pin interface configuration.
0,4,4 RLL 144-bit Reed Solomon 144-bit Reed Solomon Western Digital defines a megabyte (MB) as 1,000,000 bytes and a gigabyte (GB) as 1,000,000,000 bytes. Differential option available on 68-pin models. The standard is 512 byte sectors. Optionally, we will support 512-528 bytes per sector in even byte increments.
WD Enterprise WDE2170/WDE4360 Specifications 2.3. Mechanical Specifications Figure 2-1 through Figure 2-3 show the mounting dimensions and locations of the screw holes for the WDE2170 and WDE4360 drives. Figure 2-1. 50-pin Drive Dimensions Table 2-4. 50-pin Drive Dimensions Dimension Inches Millimeters 4.000...
Specifications WD Enterprise WDE2170/WDE4360 2.3.1. Mounting The WD Enterprise drives feature side and bottom mounting holes, which allow the drive to be mounted in any orientation. See Figure 2-4 for orientation axes. The hard drive is a precision mechanical assembly. Improper mounting may distort the drive frame and impair its ability to function.
The drive was track following on the OD cylinder for these measurements. This is for a ratio of four reads per one write. Differential option available on 68-pin models only. Table 2-8. WDE4360 Current Requirements and Power Dissipation Operating Current Current...
Specifications WD Enterprise WDE2170/WDE4360 2.4.2. 12V Current Profile The following graphs show the +12V current profile for the WDE2170 and WDE4360 drives during spin-up and run. Figure 2-5. WDE2170 +12V Current Profile 1 .6 S p in u p P e a k A C C u rre n t 1 .4...
WD Enterprise WDE2170/WDE4360 Specifications 2.4.3. Input Voltage Requirements The input voltage requirements for the WDE2170 and WDE4360 are as follows: + 5V 5% and + 12V 2.4.4. Ripple Table 2-9. Voltage Ripple +12 VDC +5 VDC Maximum Start: 400 mV (peak-to-peak)
Specifications WD Enterprise WDE2170/WDE4360 2.5. Environmental Specifications 2.5.1. Shock and Vibration All shock and vibration specifications apply to the mounting and orientation conditions described in section 2.3. Orientation axes are defined in Figure 2-4. Table 2-10. Shock and Vibration Shock...
Page 23
WD Enterprise WDE2170/WDE4360 Specifications Operating Vibration WD Enterprise drives are tested by applying a continuous swept sine excitation in each linear axis, one axis at a time. Sweep rate is one octave per minute. The drive incurs no physical damage and no hard errors while subjected to continuous vibration not exceeding the level listed in Table 2-10.
Specifications WD Enterprise WDE2170/WDE4360 2.5.2. Temperature and Humidity Table 2-11. Temperature and Humidity Temperature and Humidity Operating Temperature 5°C to 55°C (41°F to 131°F) Humidity 10-90% RH non-condensing 33°C (maximum wet bulb) Thermal Gradient 10°C/hour (maximum) Non-Operating Temperature -40°C to 60°C (-40°F to 140°F)
Western Digital drives are free of Polychlorinated Biphenyl (PCBs) and Cadmium materials. In addition, prohibited Chlorofluorocarbons (CFCs) are not used in the manufacturing process. Models WDE2170 and WDE4360 meet the safety standards of the following regulatory agencies: Underwriters Laboratories: UL-Standard 1950, Standard for Safety of...
Write Caching Write caching gives the host the ability to allow the drive to asynchronously write data to the media while other processes may occur. Refer to the Western Digital SCSI Implementation Guide (document number 4096-001116) for further details. 3.6.
3.9. Media Defect Management Western Digital drives support a defect management algorithm that uses sector slipping. Defective sites are pushed down during a reassignment operation to maintain a sequential order. Spare sectors are placed throughout the drive to support this algorithm.
WD Enterprise WDE2170/WDE4360 Advanced Product Features 3.13. Zoned Recording The drives employ zoned recording to increase data density on the outer tracks of the drive. Zoned recording allows the adjustment of the number of sectors per track, which provides storage of more sectors on the larger, outer tracks. Formatting packs data uniformly throughout the surface of the platter by dividing the outer tracks into more sectors.
Advanced Product Features WD Enterprise WDE2170/WDE4360 3.16. Option Block Functions The firmware uses several pins on the option block to modify the drive characteristics. The definitions for the jumpers follow: SCSI ID: Four jumpers are used to identify the default SCSI ID for the drive.
The drive firmware also implements a software ECC, which is capable of correcting single or double burst errors up to 2 bytes per interleave. Refer to the Western Digital SCSI Implementation Guide (document number 4096- 001116) for more information. 3.18. Self-Monitoring, Analysis, and Reporting Technology (S.M.A.R.T.)
Advanced Product Features WD Enterprise WDE2170/WDE4360 3.19. Hot Plug/Unplug Support The conditions for hot-plugging drives into an active SCSI bus follow: The drive signal ground must be made before the SCSI bus signals. Power—both +5V and +12V—cannot be applied until the SCSI bus signals are connected.
WD Enterprise WDE2170/WDE4360 SCSI Interface and Command Set SCSI I NTERFACE AND OMMAND Refer to the Western Digital SCSI Implementation Guide (document number 4096-001116). 4079-001045 Rev. B RELEASED 04-08-97...
The Option Block WD Enterprise WDE2170/WDE4360 PTION LOCK The WD Enterprise drive PCBA contains an option block that controls the drive’s operation. This block is equipped with jumper pins that correspond to various options controlled by SCSI commands. Jumpers are used to enable or disable the options and modify the drive configuration.
WD Enterprise WDE2170/WDE4360 The Option Block 5.3. Option Block Pin Assignments The option block is used to modify the drive characteristics. The table below shows the pin numbers that correspond to each option or signal, and provides instruction for enabling and disabling these features. Refer to the WD Enterprise Installation Guide (document number 4079-001046) for option definitions.
The Option Block WD Enterprise WDE2170/WDE4360 5.4. SCSI ID Jumper Table Table 5-2. SCSI ID Jumper Table JUMPER LOCATION SCSI ID Pins 7 & 8 Pins 5 & 6 Pins 3 & 4 Pins 1 & 2 jumper installed jumper removed legal 8-bit bus IDs* * If any device on your computer’s SCSI bus supports only 8-bit SCSI IDs, the WD Enterprise drive must be set to...
6.2. SCSI Physical Interface All Western Digital SCSI hard drives are designed to conform to the SCSI-3 Parallel Interface as described in the draft of proposed ANSI specification X3T10/855D Revision 15a. In addition, drives equipped with the 80-pin SCA connector are designed to conform to the Small Form Factor Committee draft specification SFF-8046 Rev 2.0...
SCSI Connectors WD Enterprise WDE2170/WDE4360 6.4. 68-Pin SCSI Connector Figure 6-2. 68-Pin SCSI Connector, Remote Option Connector, and Power Connector Pin Numbers D R IV E O U T L IN E RELEASED 04-08-97 4079-001045 Rev. B...
WD Enterprise WDE2170/WDE4360 SCSI Connectors Table 6-5. 68-pin SCSI Connector Pin Assignments DIFFERENTIAL SCSI CONNECTOR SINGLE-ENDED SCSI CONNECTOR (OPTIONAL) Signal Name Number Signal Name Signal Name Number Signal Name GROUND -DB12 +DB12 -DB12 GROUND -DB13 +DB13 -DB13 GROUND -DB14 +DB14...
SCSI Connectors WD Enterprise WDE2170/WDE4360 Table 6-6. Remote Option for 68-Pin Connector (single-ended and differential versions) SFF-8009 SFF-8009 Signal SFF-8009 SFF-8009 Signal Signal Signal Name Pin Number Number Pin Number Name Name Name SCSI ID 0 SEL0- XTFALT- GROUND SCSI ID 1...
Caution: Do not remove any product identification labels. The drive requires no preventive maintenance and contains no user-serviceable parts. Service and repair of the drive must be performed at a Western Digital Service Center. Contact your Western Digital representative for warranty information and service/return procedures.
If you have a problem with your WD Enterprise drive, the following tips may help determine the cause of the problem. Verify that you have correctly followed the setup procedures for your system. Check the physical installation: Jumper selections on the WDE2170 and WDE4360 Correct cabling Controller card, properly seated and configured System power supply Observe the environmental limits specified for this product.
Adaptive Caching - The drive determines the environment in which it’s being used and optimizes the way it handles commands and data. Auto Park - Turning off the drive's power causes the WDE2170/WDE4360 drive to move the read/write heads to a safe non-data landing zone and locks them in place.
Page 49
Functional Integrity Testing (FIT) - Suite of tests Western Digital performs on all its drive products to ensure compatibility with different hosts, operating systems, adapters, application programs, and peripherals.
Page 50
Glossary WD Enterprise WDE2170/WDE4360 Servo Burst - Provides positioning information to the actuator arm, usually positioned between sectors or at the end of a track. Single-ended SCSI - Standard electrical interface for SCSI. Single-ended means an interface with one signal line and one corresponding ground line for each SCSI signal.
WD Enterprise WDE2170/WDE4360 Appendix A. — Understanding the Model Number A. — U PPENDIX NDERSTANDING THE ODEL UMBER The diagram illustrates the model number convention for WD Enterprise drives. The table illustrates the interface matrix portion of the model number.