Installing the 160 mm diameter and 200 mm diameter systems 7
7.1.1
Scope of delivery of the basic set for
the shaft installation, article number
0020095533 (160 mm diameter), 0020095534
(200 mm diameter)
6
5
4
1
Shaft cover
2
Flue pipe (PP), black (no
sleeve), 500 mm long
3
Support elbow (PP) 130,
87° incl. mounting rail
7.1.2
Preparing the installation
1.
Determine the installation site of the flue gas guiding in
the shaft.
2.
Drill a sufficiently large opening to allow enough space
for installation.
3.
Drill a hole in the rear side of the shaft.
Diameter: 10 mm
0020058722_04 Air/flue gas system Installation manual
1
Ø 160
(Ø 200)
2
400
(
500)
Ø 160
(Ø 200)
3
Ø 350
4
Safety pipe for shaft open-
ing
5
Wall collar
6
Ventilation grille
7.1.3
Installing the support elbow
min. 250 mm
1
Mounting rail
2
Support elbow
3
Flue pipe
4
Installation aid
1.
Check that the mounting rail is long enough. Mounting
rails with a length of 500 mm are also available.
2.
Insert the support elbow (2) with the mounting rail (1) so
that the flue pipe is positioned in the centre of the shaft.
3.
For stability, point the opening of the mounting rail U
profile downwards.
4.
Install the flue gas pipe on a support pipe (optional).
(→ Page 25)
7.1.4
Installing the spacer
Applies to: 160 mm diameter system
Join together the individual components for the required
spacer.
7
6
5
4
3
2
1
5
Spacer
6
Inspection T-piece
7
Line
23