Fig. 4.21 Fixing the horizontal intermediate plates
1
Fig. 4.22 Fixing the upper side sections
1
1
2
Fig. 4.23 Mounting the hydraulic connection pipes
Installation manual auroTHERM 0020057148_03
2
1
2
A
a
u
With fields arranged on top of each
other
• Slide the intermediate plates into each
other (1).
2
• Slide the horizontal intermediate plates be-
tween the collector edge and the interme-
diate plate (2).
• Slide the plates over the upper edge of the
lower collector until they can be felt lock-
ing .
u
With fields arranged on top of each
other
• Slide the shorter side sections (from basic
kit, Article No. 0020059906) laterally over
the upper collector.
• Make sure that the side section is on the
collector frame and that it is locked.
• Fix the side sections to the roof battens
with the supplied brackets (1) and bolts
no. 2 using the supplied Torx bit.
n
With fields arranged side by side
• Insert the pipe couplings into the side
openings of the collector (1) up to the stop.
• Fix the pipe couplings with clamps (2).
Caution!
a
Danger of damage to the collector as
a result of incorrect assembly!
B
Make sure that the clamp (A) slides
into the slot in the pipe coupler (B).