Hydraulic Connection Preparation; Installation 4 - Vaillant auroTHERM VFK 145 H/V Installation Manual

In-roof mounting
Hide thumbs Also See for auroTHERM VFK 145 H/V:
Table of Contents

Advertisement

4.6

Hydraulic connection preparation

Fig. 4.8 Feeding the pipe through the sarking membrane
If there is a sarking membrane, proceed as follows:
• Cut the sarking membrane vee-shaped.
• Fold the upper, larger tab on the roof batten above,
and the lower, smaller tab on the roof batten below.
• Fix the sarking membrane tight to the roof batten.
This ensure that the dampness flows away to the side.
• With the roofs activated, cut out a hole with the com-
pass saw.
• Work the roofing felt as described for the sarking
membrane.
Installation manual auroTHERM 0020057148_03
4.7
Installation
• For the installation of flat collectors, prepare the fol-
lowing tools and materials.
Fig. 4.9 Installation tools: water level, cordless screwdriver,
Torx bit (TX25, supplied), drill 4.5 mm, hammer, meas-
uring tape/folding rule, rubber mallet, trimming knife,
waterproof silicone and hand riveter (supplied)
Vaillant flat collectors are available in different versions:
one for the horizontal position, one for the vertical posi-
tion.
Besides, they can be arranged in the collector field side
by side and on top of each other.
Generally, the installation steps and the instructions
described in this manual are valid for both collector
positions and field arrangements.
Any different installation steps are clearly pointed out:
w
With horizontal collector position
s
With vertical collector position
n
With fields arranged side by side
u
With fields arranged on top of each other

Installation 4

GB
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aurotherm vfk 125Aurotherm vfk 150 h/v