Vaillant auroTHERM VTK 570/2 Installation Manual

Vaillant auroTHERM VTK 570/2 Installation Manual

On-roof/flat roof installation
Hide thumbs Also See for auroTHERM VTK 570/2:

Advertisement

For the expert technician
Installation manual
auroTHERM
On-roof/flat roof installation
GB
VTK 570/2
VTK 1140/2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the auroTHERM VTK 570/2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vaillant auroTHERM VTK 570/2

  • Page 1 For the expert technician Installation manual auroTHERM On-roof/flat roof installation VTK 570/2 VTK 1140/2...
  • Page 2: Table Of Contents

    Fitting the collectors ..........23 Flat-roof mounting ........28 Weighting and arrangement of the frames ... 28 Fitting the collectors ..........32 Final operations ..........37 Recycling and disposal ........ 38 Vaillant Customer Service and warranty . 38 Vaillant warranty..........38 Vaillant service ............. 38...
  • Page 3: Notes On The Documentation 1

    The collectors may only be operated with Vaillant ready- Symbols used mixed solar fluid. Passing heating water or hot water di- Please observe the safety instructions in this installation rectly through the collectors is not permitted.
  • Page 4: Safety Instructions

    2 Intended use 3 Safety instructions On-roof mounting: Related documents The tube collectors can be mounted at an angle of Designers and installers should refer to current informa- 15° – 75°. tion and standards. A useful reference would be the en- An installation angle of less than 15°...
  • Page 5: Lightning Protection

    Never fill or flush the collector with water. Only Alternatively, install the Vaillant Solar auto- fill and flush the collector with Vaillant ready- matic air vent (article number 302019) in the mixed solar fluid. highest point of the system or the automatic...
  • Page 6: Scope Of Delivery

    4 Before installation Scope of delivery • Check the mounting kit for completeness based on the illustrations and bills of materials. 4.2.1 On-roof mounting Fig. 4.1 On-roof mounting kit Pos. Description Quantity Article number (kit) Rail kit VTK 1140/2 0020076781 Rail kit VTK 570/2 0020076780 Tube collector VTK 570/2...
  • Page 7: Flat-Roof Mounting

    Before installation 4 4.2.2 Flat-roof mounting Fig. 4.2 Flat roof mounting kit Pos. Description Quantity Article number (kit) Rail kit VTK 1140/2 0020076781 Rail kit VTK 570/2 0020076780 Open air installation, VTK 0020076778 0020059904 (2 pcs.) Gravel tray kit 0020059905 (3 pcs.) Tube collector VTK 570/2 0010002227 Tube collector VTK1140/2...
  • Page 8: Assembling The Collector Array

    4.3.1 On-roof mounting When mounted on the roof, Vaillant tube collectors can be arranged above one another in up to 3 rows. 4.3.1.1 Collector arrangement, 1-row Fig. 4.3 Installation kit for single row on-roof mounting...
  • Page 9 Before installation 4 Number of collectors Connecting kit VTK (basic module) Part No. 0020076785 Connecting kit VTK (expansion module) Part No. 0020076779 Bracket kit Type P (pantile) Part No. 0020067273 Bracket kit Type S Part No. 0020067275 Bracket kit Type S flat Part No.
  • Page 10: Collector Arrangement, 2-Row

    4 Before installation 4.3.1.2 Collector arrangement, 2-row Fig. 4.4 Installation kit for 2-row on-roof mounting (here: VTK 570/2) Number of collectors per row Number of rows Connecting kit VTK (basic module) Part No. 0020076785 Connecting kit VTK (expansion module) Part No. 0020076779 Bracket kit Type P (pantile) Part No.
  • Page 11: Collector Arrangement, 3-Row

    Before installation 4 Number of collectors per row Number of rows Connecting kit VTK (basic module) Part No. 0020076785 Connecting kit VTK (expansion module) Part No. 0020076779 Bracket kit Type P (pantile) Part No. 0020067273 Bracket kit Type S Part No. 0020067275 Bracket kit Type S flat Part No.
  • Page 12 4 Before installation Number of collectors per row Number of rows Connecting kit VTK (basic module) Part No. 0020076785 Connecting kit VTK (expansion module) Part No. 0020076779 Bracket kit Type P (pantile) Part No. 0020067273 Bracket kit Type S Part No. 0020067275 Bracket kit Type S flat Part No.
  • Page 13: Flat-Roof Mounting

    Before installation 4 4.3.2 Flat-roof mounting Number of collectors Connecting kit VTK (basic module) Part No. 0020076785 Connecting kit VTK (expansion module) Part No. 0020076779 Mounting kit for open-air installation on a flat roof Part No. 0020076778 Gravel trays required Gravel tray kit (2 pcs.) Part No.
  • Page 14: Interconnection Scheme

    4 Before installation Interconnection scheme Note Observe the planning information when dimen- sioning the array volume flow. Furthermore, observe the following rules: • Connect a maximum of 14x VTK 570/2 (corresponding to an aperture area of 14 ) in series. max.
  • Page 15 (hot side) of each individual array. These will be used for venting the in- dividual arrays during commissio- ning. Only use the Vaillant stop valve, Part No. 0020076784 Caution! Danger of damage to the material as a result of incorrect assembly! Fig.
  • Page 16: Preparing The Hydraulic Connection

    When installing the roof sealing surfaces, make sure the roof skin is adequately protected. When mounted on the roof, the Vaillant tube collectors in the collector array can be arranged side-by-side or • Place large protection mats under the system.
  • Page 17: Fitting The Brackets

    On-roof mounting 5 Fitting the brackets For collectors arranged side-by-side • Mount the anchors for the mounting rails at the fol- lowing distances: Note During final fixing the pre-assembly dimension A is reduced by approx. 20 - 25 mm. Take care that there is adequate clearance on the an- chors, therefore.
  • Page 18 5 On-roof mounting For collectors arranged on top of each other • Mount the anchors for the mounting rails at the fol- lowing distances: Note During final fixing the pre-assembly dimension A is reduced by approx. 20 - 25 mm. Take care that there is adequate clearance on the an- chors, therefore.
  • Page 19: Bracket Type P (Pantile)

    On-roof mounting 5 5.2.1 Bracket Type P (pantile) Fig. 5.3 Bracket type P Lower bracket 2 Upper bracket 3 Central bracket The bracket type P can be fixed to the rafters (Pos. A) or by use of the long rear plate set 0020080177 can be offset to suit tile profile.
  • Page 20: Fixing To The Roof Batten

    5 On-roof mounting Note With some roof covering it may be necessary to offset the roof bracket to the left or right of the rafter, to do this use the accessory: Part No. 0020080177 (not available in every country). Observe the appropriate installation manual.
  • Page 21: Bracket Type S (For High Profile Pantiles)

    On-roof mounting 5 5.2.2 Bracket Type S (for high profile pantiles) Caution! Before installation on the roof batten, check the load capacity of the roof batten! If necessary, replace the roof batten. Fig. 5.6 Fixing the bracket type S 1. Uncover the rafters or the roof batten where needed. 3.
  • Page 22: Hanger Bolt Fixing Kit

    5 On-roof mounting 5.2.3 Hanger bolt fixing kit Caution! Before installation check the load-bearing ca- pacity of the wooden substructure! If necessary, strengthen it. Only for use on roof structures with timbers large enough to accept stair bolt. Fig. 5.8 Fixing with stair bolt 4.
  • Page 23: Fitting The Collectors

    On-roof mounting 5 Fitting the collectors • Fix the horizontal mounting rails with the frame clamping elements on the brackets. Note For the vertical spacing between the brackets please see Tables 5.1 and 5.2. Note For a better visual appearance, posi- tion the lower rail as low as possible on the bracket.
  • Page 24 5 On-roof mounting • Place the collector with the lower edge on the mounting rail and hook it to the clam- ping elements. • Make sure that the upper part (1) of the clamping element is above the collector rail. •...
  • Page 25 On-roof mounting 5 • Place the next collector on the lower mounting rail. • Make sure that the upper part (1) of the clamping element is above the collector rail. • Tighten the lower clamping elements on the collector. • Slide the upper mounting rails and clam- ping elements little by little from the top against the collector.
  • Page 26 5 On-roof mounting For collectors arranged on top of each other • Slide the central mounting rail flush with the lower collector (1). • Make sure that the hook of the clamping element (3) is above the edge of the colle- ctor.
  • Page 27 On-roof mounting 5 • For systems with collector sensors: Plug the collector sensor into the opening provi- ded on the flow side of the collector (hot side). With several rows of collectors: • Connect the rows of collectors in accor- dance with the interconnection schemes (cf.
  • Page 28: Flat-Roof Mounting

    6 Flat-roof mounting Flat-roof mounting With flat roof installation, the tube collectors are fas- tened to frames. The flat roof frames allow for a flexible installation with an angle of 30 °, 45 ° or 60 °. Also note that the height of the mounting rails is varia- ble, in order to compensate for small floor irregularities.
  • Page 29 Flat-roof mounting 6 For the required space and the distances between frames please see Tables 6.2 to 6.4. VTK 570/2 [distances in mm] Number of 30° 45° 60° collectors (28.5°) (42.5°) (59.5°) ±30 1168 1875 2582 3289 3996 4703 5410 6117 6824 7531...
  • Page 30 6 Flat-roof mounting VTK 1140/2 [distances in mm] 30° 45° 60° Number of collectors ±30 1170 2548 3945 5342 1072 2950 1432 3940 1757 4830 2460 1274 1397 6739 8136 9533 1) Angle of attack 30°, 45° or 60° 2) Solar altitude of 20° (winter sun) 3) Dimension A may vary in conjunction with dimensions D and E by 30 mm 4) 5 mm Table 6.3 Dimensions for VTK 1140/2 [in mm]...
  • Page 31 Flat-roof mounting 6 VTK 1140/2 and VTK 570/2 in combination [distances in mm] VTK 1140/2 VTK 570/2 Number of 30° 45° 60° collectors ±30 570/2 1140/2 1170 2548 3945 1072 2950 1432 3940 1757 4830 2460 1397 1274 5342 6739 8136 1) Angle of attack 30°, 45°...
  • Page 32: Fitting The Collectors

    6 Flat-roof mounting Fitting the collectors • Open the frames. Caution! Follow Tables 6.1 to 6.4 without ex- ception to determine the required weights! With screwed connection on the roof: • Fasten the rear section to the base section with a retaining pin and locking clip. Fig.
  • Page 33 Flat-roof mounting 6 If gravel trays are used: VTK 1140/2 VTK 570/2 • Place large protection mats under the sys- tem. • Set up the frames (1) according to the num- ber of collectors to be mounted. Note The weights and distances can be found in Table 6.1.
  • Page 34 6 Flat-roof mounting • If multiple collectors are mounted, have the mounting rails (1) meet in the centre of the frames (2) (A). • On the first and last frame, the mounting rails (1) should project by 20 mm over the edge (B).
  • Page 35 Flat-roof mounting 6 • Remove the carrying straps. Fig. 6.11 Removing the carrying straps • Place the next collector on the lower moun- ting rail at a distance of approx. 10 cm from the first collector. Fig. 6.12 Mounting other collectors •...
  • Page 36 6 Flat-roof mounting • Slide the upper mounting rails towards the collectors. • Take care that the upper parts (1) of the clamping elements are over the rails on the collectors. • Tighten the clamping element with the socket/combination wrench (13 mm AF). Caution! After tightening the clamping ele- ments, make sure the tension is cor-...
  • Page 37: Final Operations 7

    Flat-roof mounting 6 Final operations 7 After commissioning: • Insulate the hydraulic connections with the Armeflex insulation (1) (from the VTK ex- pansion module connecting kit, Part No. 0020076779). • Cover the insulation with the cover clip (2) (from the VTK expansion module connec- ting kit, Part No.
  • Page 38: Recycling And Disposal

    8 Disposal 9 Vaillant Customer Service and warranty Recycling and disposal The development of all Vaillant products takes into ac- count the future with regard to use of materials that can be easily recycled with the least detrimental affects upon our environment. The packaging makes maximum...
  • Page 39 Technical data 10 10 Technical data Units VTK 570/2 VTK 1140/2 Number of vacuum tubes 64.2 (aperture), DIN4757-4 or EN12975 with wind, relative to aperture W/(m 0.885 with wind, relative to aperture W/(m 0.001 (50°), relative to aperture ,trans (50°), relative to aperture ,long Predicted energy gain (location Würzburg, 5m kWh/m...
  • Page 40 10 Technical data VTK 570/2 Fig. 10.1 Dimensional drawing VTK 570/2 Installation manual auroTHERM 0020077994_00...
  • Page 41 Technical data 10 VTK 1140/2 1392 Fig. 10.2 Dimensional drawing VTK 1140/2 Fig. 10.3 Efficiency of the VTK 570/2 and the 1140/2 at an ir- radiance Eg of 300 W/m K Efficiency [%] 'T = T Collector Ambient air Installation manual auroTHERM 0020077994_00...
  • Page 42 10 Technical data Fig. 10.4 Efficiency of the VTK 570/2 and the 1140/2 at an ir- radiance Eg of 800 W/m K Efficiency [%] 'T = T Collector Ambient air p [mbar] VTK 570/2 VTK 1140/2 Q [l/h] Fig. 10.5 Pressure loss graph Q Mass flow [l/h] 'p Pressure loss [mbar] Installation manual auroTHERM 0020077994_00...