Page 1
USER MANUAL MODEL 2026P Parallel to Serial/ Serial to Parallel Interface Converter Part #07M2026P-C SALES OFFICE Doc. #102141UC (301) 975-1000 Revised 6/8/98 TECHNICAL SUPPORT C E R T I F I E D (301) 975-1007 An ISO-9001 http://www.patton.com Certified Company...
Patton Electronics Technical Support at (301) 975-1007. 3.1 CONFIGURATION SWITCHES 2.1 FEATURES The Model 2026P uses a set of eight internal DIP switches (see Figure 1) that allow configuration to a wide range of applications. You • Converts parallel data to serial data and vice versa must open the case to gain access to the internal switches.
Page 4
BERT Activated BERT De-activated NOTE: When you activate the BER Test, the 2026P “memorizes” the setting of Switches S1, S3,S4, S5, S6, S7, and S8 to perform the test. If you modify any of these switches, you must de-activate Switch 2 in order for the changes to take effect.
The 120VAC U.S. wall transformer version supplies +9V regulated DC up to 500mA. Connect this wall transformer to the Model 2026P by means of a cannon jack on the side panel. The Model 2026P is powered-up as soon as it is plugged into an AC outlet–there is no power switch.
Page 6
APPENDIX B APPENDIX C PATTON MODEL 2026P INTERFACE CONNECTIONS PATTON MODEL 2026P FACTORY REPLACEMENT PARTS AND ACCESSORIES 36 PIN CENTRONICS PARALLEL PORT CONNECTIONS Description Direction Patton Model # Description Strobe Output 08059DCI ......230VDC (+9V ±5% reg. DC/500mA) Data bit 0...