WARNING!
• Installation by qualified personnel only.
• Speakers must be wired in parallel and
connected to the correct line terminals of
amplifier.
• Ensure that all speakers have the same
polarity with respect to each other.
• The sum of the nominal power values of
all the speakers connected must not
exceed 80% of the amplifier's rated
output.
• Do not select another power tap while the
speaker is in use!
• No open flame sources, such as lighted
candles, should be placed on the
apparatus.
Safety First!
Before connecting and using the equipment, please
read this Quick-Start Guide carefully and keep it for
future reference.
WARNING! This equipment has been
designed to be installed by qualified
professionals only! There are many factors to
be considered when installing professional
WARRANTY
Warranty: LOUD Technologies Inc. requires its authorized EAW Commercial distributors to abide by the
following warranty terms for all EAW Commercial brand products (all dates are from the date of delivery
from an Authorized EAW Commercial Distributor to the end user/installation site): Loudspeakers – 5 years;
Active Electronics – 5 years; Accessories – 2 years.
What Is Covered: Defects in workmanship and materials and against malfunctions. EAW Commercial
distributors must remedy all such defects and malfunctions without charge for parts or labor if the warranty
applies. Final determination of warranty coverage lies solely with each authorized EAW Commercial
distributor.
What Is Not Covered: This warranty does not extend to damage or malfunctions resulting from, but not
limited to, shipment, improper installation, misuse, neglect, abuse, normal wear, accident, or to any product
on which the serial number has been modified or removed. Exterior defects in or damage to the exterior
appearance are specifically excluded from this warranty. EAW Commercial distributors shall not be liable for
incidental or consequential damages resulting from the use of EAW Commercial products. Repairs and/or
modifications by other than an Authorized EAW Commercial Distributor automatically voids this warranty.
CAUTION: To avoid the risk of electric
shock, never allow this equipment to be
exposed to rain or dampness.
• To ensure normal cooling of the PH10,
make sure the unit is well ventilated.
Maintain a minimum distance of
1.2 in/30 mm around the apparatus for
sufficient ventilation.
• Avoid exposure to direct sunlight or
proximity to any heat source, dust, or
dampness.
• To prevent damage, do not use this
speaker with its front pointing upward.
sound reinforcement systems. Some of these
factors include mechanical and electrical
considerations, as well as acoustic coverage
and performance. LOUD Technologies strongly
recommends that this equipment be installed
only by a professional sound installer or
contractor.