Download Print this page

Battery Installation - Visonic WT-100 Installation Instructions

Universal wireless transmitters

Advertisement

3.5 Wiring
 
Normally closed sensors and inertial vibration detectors are wired
in series between the terminals marked N.C.
Note: If the N.C. input is not used, it must be shorted by installing
a jumper on the N.C. header below the terminal block (Fig. 1).
Normally open alarm contacts should be wired in parallel with the
terminals marked N.O..
Visonic
Ltd.
low
current
SRN-2000C/PC series PIR
detectors may be powered
from the 1st (+) and 2nd (–)
terminals
from
the
left.
When
using
the
same
battery for the transmitter
and
the
PIR
detector,
low-battery supervision is
obtained for both units.
To use the reed switch, remove the reed switch jumper "J1"
(located near the reed switch).

3.6 Battery Installation

Note: Before installing the battery, use some masking tape to
temporarily keep the tamper switch lever down. This will prevent
the unit from continuously transmitting a tamper alert while the
front cover is removed for testing.
The units are powered by a 9-volt alkaline or lithium battery.
For proper operation, use only an alkaline or lithium battery.
Snap the battery clip onto the battery terminals and put the
battery in place (above the PC board).
4 4 4 4 . MISCELLANEOUS COMMENTS
. MISCELLANEOUS COMMENTS
. MISCELLANEOUS COMMENTS
. MISCELLANEOUS COMMENTS
4.1 Product Limitations
Visonic Ltd. wireless systems are very reliable and are tested to
high standards. However, due to low transmitting power and
limited range (required by FCC and other regulatory authorities),
there are some limitations to be considered:
A. A receiver may be blocked by radio signals sent on or near its
operating frequency, regardless of the digital code used.
B. A receiver responds to one transmitted signal at a time.
C. Wireless equipment should be tested regularly to determine
whether there are sources of interference and to protect
against faults.
4.2 Compliance with Standards
The 315 MHz model of this device contains RF module RFT-1A,
which complies with Part 15 of the FCC Rules and RSS-210 of
WARRANTY
WARRANTY
WARRANTY
WARRANTY
Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its
products hereinafter referred to as "the Product" or "Products" to be in conformance with
its own plans and specifications and to be free of defects in materials and workmanship
under normal use and service for a period of twelve months from the date of shipment by
the Manufacturer. The Manufacturer's obligations shall be limited within the warranty
period, at its option, to repair or replace the product or any part thereof. The Manufacturer
shall not be responsible for dismantling and/or reinstallation charges. To exercise the
warranty the product must be returned to the Manufacturer freight prepaid and insured.
This warranty does not apply in the following cases: improper installation, misuse,
failure to follow installation and operating instructions, alteration, abuse, accident or
tampering, and repair by anyone other than the Manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or
liabilities, whether written, oral, express or implied, including any warranty of
merchantability or fitness for a particular purpose, or otherwise. In no case shall the
Manufacturer be liable to anyone for any consequential or incidental damages for breach
of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not
authorize any person to act on its behalf in the modification, variation or extension of this
warranty. This warranty shall apply to the Product only. All products, accessories or
attachments of others used in conjunction with the Product, including batteries, shall be
covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or
otherwise, caused by the malfunction of the Product due to products, accessories, or
attachments of others, including batteries, used in conjunction with the Products.
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 730-0800 FAX: (0870) 730-0801
www.visonic.com
INTERNET:
© VISONIC LTD. 2001
WT-100
D-2001-0
2
Figure 5. Terminal Block Wiring
NEW: DE2001- (REV. 5, 3/01)
3.7 Testing
 
A. Select the desired system code as instructed in Section 3.2.
B. Select a channel code as instructed in Section 3.3.
C. Activate the sensor connected to the transmitter input.
Note: If a vibration detector is used, adjust the sensitivity with
the SENSE control (see Section 3.4).
D. Verify that the transmitter LED lights during transmission.
E. WT-100: Leave the sensor input disturbed for several
minutes. Verify that the unit repeats the transmission for
approximately 2 seconds each minute.
WT-100A: As with WT-100, but verify transmission only once.
F. Check whether the receiver's LED lights steadily, indicating
good detection of the RF signal.
G. Verify that the receiver's corresponding relay energizes while
receiving a signal.
H. Restore the transmitter's input to its undisturbed state, set all
4 channel switches to OFF and initiate a transmission. This
should cause the low-battery alert buzzer at the receiver to
sound (provided that a buzzer is connected to the receiver).
I. Re-select the desired channel code with the four channel
switches.
J. Remove the masking tape used to hold down the tamper
switch lever. The transmission triggered by the tamper switch
should cause channel 2 relay of the receiver to energize.
K. Carefully position the front cover hole over the LED. Secure
the front cover to the base with the screw and insert the
plastic cap into the hole (Fig. 2).
Industry and Science Canada. Operation is subject to these two
conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received,
including interference that may cause undesirable operation.
The user is cautioned that changes or modifications to the
unit, not expressly approved by Visonic Ltd., could void the
user's FCC or other authority to operate the equipment.
This device complies with the essential requirements and provisions
of Directive 1999/5/EC of the European Parliament and of the Council
of 9 March 1999 on radio and telecommunications terminal
equipment.
Frequency Allocations for Wireless Devices in European Countries:
• 433.92 MHz has no restriction in any EU member state.
• 418 MHz is allowed in the UK only.
• 315 MHz is not allowed in any EU member state.
The Manufacturer does not represent that its Product may not be compromised and/or
circumvented, or that the Product will prevent any death, personal and/or bodily injury
and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the
Product will in all cases provide adequate warning or protection. User understands that a
properly installed and maintained alarm may only reduce the risk of events such as
burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such
will not occur or that there will be no death, personal damage and/or damage to property
as a result.
The Manufacturer shall have no liability for any death, personal and/or bodily injury
and/or damage to property or other loss whether direct, indirect, incidental,
consequential or otherwise, based on a claim that the Product failed to function.
However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause or origin, the
Manufacturer's maximum liability shall not in any case exceed the purchase price of the
Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the
complete and exclusive remedy against the Manufacturer.
Warning: The user should follow the installation and operation instructions and among
other things test the Product and the whole system at least once a week. For various
reasons, including, but not limited to, changes in environmental conditions, electric or
electronic disruptions and tampering, the Product may not perform as expected. The user
is advised to take all necessary precautions for his /her safety and the protection of
his/her property.
6/91
DE2001

Advertisement

loading

This manual is also suitable for:

Wt-100a