Sonifex SignalLED Series User Handbook Manual

Led single flush mounting sign
Hide thumbs Also See for SignalLED Series:
Table of Contents

Advertisement

Quick Links

SignalLED
User Handbook
This handbook is for use with the following stock codes:
LD-20F1REC
LED Single Flush Mounting 20cm RECORD sign
LD-20F1ONA
LED Single Flush Mounting 20cm ON AIR sign
LD-20F1MCL
LED Single Flush Mounting 20cm MIC LIVE sign
LD-40F1REC
LED Single Flush Mounting 40cm RECORD sign
LD-40F1ONA
LED Single Flush Mounting 40cm ON AIR sign
LD-40F1MCL
LED Single Flush Mounting 40cm MIC LIVE sign
LD-40F1PHN
LED Single Flush Mounting 40cm PHONE sign
LD-40F1TRF
LED Single Flush Mounting 40cm TRAFFIC
FLAG sign
LD-40F1ADB
LED Single Flush Mounting 40cm AD BREAK sign
LD-40F1REH
LED Single Flush Mounting 40cm REHEARSAL sign
LD-40F1DOR
LED Single Flush Mounting 40cm DOOR sign
LD-40F1OBT
LED Single Flush Mounting 40cm OBIT sign
LD-40F1NOE
LED Single Flush Mounting 40cm NO ENTRY sign
LD-40F1EXIT
LED Single Flush Mounting 40cm EXIT sign
LD-40F1SIL
LED Single Flush Mounting 40cm SILENCE sign
LD-40F1MET
LED Single Flush Mounting 40cm MEETING
IN PROGRESS sign
LD-40F1INT
LED Single Flush Mounting 40cm
INTERVIEW IN PROGRESS sign
LD-40F2TX-REH
Twin Flush Mounting Signs 2x20cm
Twin 'TX' & ' REH' sign
LD-40F2ONA-MCL Twin Flush Mounting Signs 2x20cm
Twin 'ON AIR' & 'MIC LIVE' sign
LD-40F2ONA-SIL
Twin Flush Mounting Signs 2x20cm
Twin 'ON AIR' & 'SILENCE' sign
LD-40E1REC
SignalLED double sided end mounting 40cm
RECORD sign
LD-40E1ONA
SignalLED double sided end mounting 40cm
ON AIR sign
LD-40E1MCL
SignalLED double sided end mounting 40cm
MIC LIVE sign
LD-40E2
SignalLED twin double sided end mounting
2 x 20cm sign
LD-KE1
SignalLED conversion kit, single flush mount
to end mount
LD-KC1
Ceiling Mounting For 40cm Or 20cm Flush
Mounting Signs
LD-IT
SignalLED end mount sign installation tool

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SignalLED Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sonifex SignalLED Series

  • Page 1 SignalLED User Handbook This handbook is for use with the following stock codes: LD-20F1REC LED Single Flush Mounting 20cm RECORD sign LD-20F1ONA LED Single Flush Mounting 20cm ON AIR sign LD-20F1MCL LED Single Flush Mounting 20cm MIC LIVE sign LD-40F1REC LED Single Flush Mounting 40cm RECORD sign LD-40F1ONA LED Single Flush Mounting 40cm ON AIR sign...
  • Page 2 Information in this document is subject to change without notice and does not represent a commitment on the part of the vendor. Sonifex Ltd shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual.
  • Page 3: Table Of Contents

    CONTENTS Warranty Information Introduction Safety Information Handling Notes Power Supply Approval Documents Installation Mounting The Sign Opening The End Covers LD-20F1 & LD-40F1 Flush Sign Mounting Requirements LD-40E1 & LD-40E2 End Mounting Requirements LD-KC1 Ceiling Mounting Kit Connecting The Power and Signal Connections For Flush Mounted Signs Connecting The Power &...
  • Page 4 FI GU RE S Figures Fig 1-1: Australia Certificate of Approval, (this is a three page document) Fig 1-2: CB Certificate of Approval, (this is a two page document) Fig 1-3: CE Certificate of Approval, (this is a ten page document) Fig 1-4: UL Certificate of Approval, (this is a one page document) Fig 2-1: LD-20F1 &...
  • Page 5: Warranty Information

    In order to register the date of purchase so that we can keep you informed of any design improvements or modifications, it is important to complete the warranty registration document that is enclosed and return it to Sonifex Ltd in the UK. For your own records you should write down the serial number of the SignalLED sign.
  • Page 6: Power Supply Approval Documents

    The power supply used with the SignalLEDs is UL, EC and CC approved. For a more detailed view of the certificates, please check online at: http://www.sonifex.co.uk/ signalled/index.shtml Fig 1-1: Australia Certificate of Approval Fig 1-2: CB Certificate of Approval SignalLED User Handbook...
  • Page 7 P OW E R SU P P LY APPROVAL DOCUMENTS Fig 1-3: CE Certificate of Approval Fig 1-4: UL Certificate of Approval SignalLED User Handbook...
  • Page 8: Installation

    INSTA LL ATIO N Installation Mounting The Sign Route the signal and power supply cables before finalising the mounting of the sign. These cables can be routed either through the aperture, or through the cable cut-outs in the back of the wall mount moulding. The LED sign should be mounted on a firm solid surface.
  • Page 9: Ld-40E1 & Ld-40E2 End Mounting Requirements

    I N S TAL L AT I ON LD-40E1 & LD-40E2 End Mounting Requirements Ceiling = Wall Mounting Plate shown in red 38mm minimum = Wall Mounting Holes = Hanger Slots 44mm To create an attractive invisible-fixing finish, the SignalLED assembly is clipped into a wall mount plate.
  • Page 10: Connecting The Power And Signal Connections For Flush Mounted Signs

    INSTA LL ATIO N Connecting The Power and Signal Connections For Flush Mounted Signs To get access to the cable connection block and the mode switches which are on the PCB inside the sign, the door on the underside of the end plastic moulding must be opened. To open the door push the clip towards the sign and pull down on the small lip, see Fig 2-5.
  • Page 11: Connecting The Power & Signal Connections For End Mounted Signs

    I N S TAL L AT I ON Connecting The Power & Signal Connections For End Mounted Signs It is recommended that the LD-IT SignalLED end mount sign installation tool is used to assist the termination of the power and signal connections. The tool is designed to hold the sign on the pre-fitted wall mount plate leaving both hands free to make the connections, as shown in Fig.
  • Page 12 INSTA LL ATIO N The signalling inputs are used to control the sign and are pulled low (to 0V, pin 3) to activate. Please note pins 3 (0V) and 1 (input 1) are linked by default so that the sign will illuminate in its default mode when first powered up.
  • Page 13: Programming Colour & Illumination Modes

    PROGR AMMING Programming Colour & Illumination Modes Although the SignalLED is delivered as standard to indicate a certain colour when a pull-low display modes and uses. For example, the sign can be made to switch between 4 colours, one for each of the input conditions below. The sign can also illuminate a certain colour when no input signal is connected, i.e.
  • Page 14: Colour

    PROGR AMMING 2. Colour To choose the colour of the sign set the switches as follows: Colour SWT4 SWT5 SWT6 SWT7 SWT8 Previous DIPSwitches 1 2 3 4 5 6 7 8 DIPSwitches 1 2 3 4 5 6 7 8 DIPSwitches Green 1 2 3 4 5 6 7 8...
  • Page 15: Load Colour Settings

    PROGR AMMING 2-1. Load Colour Settings Once the DIPSwitches are set in the required state, toggle SW1 (i.e. DIPSwitch SW1 On and DIPSwitches DIPSwitches then 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Previous 3.
  • Page 16: Setting The Illumination Mode

    PROGR AMMING 4. Setting the Illumination Mode Illumination SWT4 SWT5 SWT6 SWT7 SWT8 Previous Mode DIPSwitches Constantly 1 2 3 4 5 6 7 8 Flashing DIPSwitches (0.5 sec on, continuous) 1 2 3 4 5 6 7 8 Pulsing DIPSwitches in 0.5 sec, 1 2 3 4 5 6 7 8...
  • Page 17: Technical Specifications

    TEC H NI C AL S P E CI F I C AT IO N Technical Specifications Physical Specification Power Supply: Plug-top power supply providing 6V at 1A, with 4 international wall adapters (UK, EU, US and AUS) and 5m lead to bare ends. Power Input: 5-7V DC 40cm Sign:...
  • Page 18: Appendix 1

    APPEN DICES Appendix 1 LD-KE1 SignalLED Conversion Kit, Single Flush Mount to End Mount To convert the LD-20F & LD-40F style flush mount single sided signs into single sided end mount signs you will need to fit the LD-KE1 conversion kit. Please follow these instructions carefully.
  • Page 19: Fig 5-2: Kit Components Used For The Conversion

    A P P EN D I CE S Align the 4 pins of the extrusion end cover with the screw holes in the exposed end of the aluminium tube. Note the orientation of the cut-out with the clear sign board and press fit the end cover fully onto the aluminium tube.
  • Page 20: Left Hand Side Fitting Of The Conversion Kit

    APPEN DICES Fig 5-4: Removing the Right Hand Flush Wall Moulding Fig 5-5: Right Hand Conversion Re-Assembly Left Hand Side Fitting of the Conversion Kit Note: With this conversion you will be removing the PCB from the sign so full anti-static precautions must be taken to protect the PCB from damage.
  • Page 21: Fig 5-6: Left Hand Conversion Re-Assembly

    A P P EN D I CE S This combination is then fixed to the left hand flush mount assembly end moulding with the 4 supplied No.4 x ¾ self tap screws. Do not substitute any other screws in these positions and do not reuse the screws removed from these positions because they will not support the sign correctly.
  • Page 22: Appendix 2

    APPEN DICES Appendix 2 SignalLED Preconfigurations Please note that your SignalLED sign has been preconfigured for the following operation, depending on the sign chosen. Master Top Level Part Input 1 (Default link between pins 1 Slave (Side with No Input Number and 3 on the power connector) connections)
  • Page 23 A P P EN D I CE S SignalLED Preconfigurations (continued...) Top Level Part Input 2 Both Inputs Number Turns the whole sign solid green LD-20F1MCL when connected to 0V Turns the whole sign solid red LD-20F1ONA when connected to 0V Turns the whole sign solid green LD-20F1REC when connected to 0V...
  • Page 24 w w w . s o n i f e x . c o . u k t:+44 (0)1933 650 700 f:+44 (0)1933 650 726 s a l e s @ s o n i fe x . co. u k...

Table of Contents