Page 2
Information in this document is subject to change without notice and does not represent a commitment on the part of the vendor. Sonifex Ltd shall not be liable for any loss or damage whatsoever arising from the use of information or any error contained in this manual.
If The Sign Appears To Be Off Resetting The Sign to Factory Defaults Technical Specifications Appendix 1 LD-KE1 SignalLED Conversion Kit, Single Flush Mount to End Mount Right Hand Side Fitting of the Conversion Kit Left Hand Side Fitting of the Conversion Kit Appendix 2...
Page 4
Fig 5-1: Sign Components to be Converted Fig 5-2: Kit Components Used for the Conversion Fig 5-3: Removing the Left Hand Assembly Fig 5-4: Removing the Right Hand Flush Wall Moulding Fig 5-5: Right Hand Conversion Re-Assembly Fig 5-6: Left Hand Conversion Re-Assembly SignalLED User Handbook...
Mark. This equipment operates in a horizontal position. Handling Notes The SignalLED sign should be installed in an area which is not subject to excessive heat or cold. Also, you should avoid installing it in atmospheric conditions which are dusty, smoky, or dirty, or where there is moisture or vibration.
The power supply used with the SignalLEDs is UL, EC and CC approved. For a more detailed view of the certificates, please check online at: http://www.sonifex.co.uk/ signalled/index.shtml Fig 1-1: Australia Certificate of Approval Fig 1-2: CB Certificate of Approval SignalLED User Handbook...
= Mounting hole Fig 2-1: LD-20F1 & LD-40F1 Flush Sign Mounting Requirements An absolute minimum of 60mm is required for the opened end cap, a right angled screwdriver would be needed to screw (unscrew) the end cap retaining screw. SignalLED User Handbook...
Once located, hold the sign around the end moulding of the SignalLED assembly (where the door is fitted) and press down into its final position. The sign retaining pins will clip into the indentations on the side of the wall mount plate and this should result in a click as the plastic pins move into their final position.
Do not attempt to remove the door from the end moulding. Access to the connection block and the mode switches is possible with the door fully open. Fig 2-4: Cable Routing Cut-Outs Fig 2-5: Opening The Access Door Connection Block IR Receiver Input LED Indicators Fig 2-6: Mode Settings & Connection Block SignalLED User Handbook...
Connecting The Power & Signal Connections For End Mounted Signs It is recommended that the LD-IT SignalLED end mount sign installation tool is used to assist the termination of the power and signal connections. The tool is designed to hold the sign on the pre-fitted wall mount plate leaving both hands free to make the connections, as shown in Fig.
Page 12
It will click into place when it is fully home. After all of the terminations have been checked and the cables have been routed through the cable clamps, close the end cover by reversing the opening procedure, taking care not to overtighten the retaining screw. SignalLED User Handbook...
LD-RPC. Please contact your Sonifex distributor for ordering information. Although the SignalLED is delivered as standard to indicate a certain colour when a pull-low (to 0V) input signal is applied, the sign is programmable to allow a number of different display modes and uses.
Sections 1 and 2. Section 1 initially consists of the 9 LEDS closest to the opening, with Section 2 being the 9 LEDs furthest away (on a 40cm sign). Dead Section 2 Section 1 Zone Fig 3-3: Operation of DIVIDE SignalLED User Handbook...
COLOUR (5) button to select Section 1. Pressing the colour button again alternates the currently selected section. below. Normally the User colour setting is undefined and therefore not selectable. However, for special orders Sonifex can create distinct colour sets and these will use the User colour setting. Colour Number...
The sign can be set back to the factory default colours and illumination mode as follows: Enter the Programming Mode and press and hold the MODE (3) button for 10 seconds. The sign will now show the original colour(s) and mode(s). SignalLED User Handbook...
As standard the SignalLED PCB is fitted into the right hand end of the LD-20F & LD-40F (see Fig 5-1). If you would like the sign to be viewable with the right hand side of the sign mounted onto the wall please use the ‘Right Hand Side’...
8) Please refer to the installation notes for the LD-40E style signs to complete the final fitting and colour/configuration set-up. Fig 5-2: Kit Components Used for the Conversion Fig 5-3: Removing the Left Hand Assembly SignalLED User Handbook...
10) Please refer to the installation notes for the LD-40E style signs to complete the final fitting and colour/configuration set-up. Fig 5-6: Left Hand Conversion Re-Assembly SignalLED User Handbook...
APPEN DICES Appendix 2 SignalLED Preconfigurations Please note that your SignalLED sign has been preconfigured for the following operation, depending on the sign chosen. Master Top Level Part Input 1 (Default link between pins 1 Slave (Side with No Input...
Page 23
A P P EN D I CE S SignalLED Preconfigurations (continued...) Top Level Part Input 2 Both Inputs Number Turns the whole sign solid green LD-20F1MCL Turns the sign off when connected to 0V Turns the whole sign solid red...
Page 24
w w w . s o n i f e x . c o . u k t:+44 (0)1933 650 700 f:+44 (0)1933 650 726 s a l e s @ s o n i fe x . co. u k...
Need help?
Do you have a question about the SignalLED and is the answer not in the manual?
Questions and answers