Installation - venting

The moist air from the dryer must be
vented via a ducting system.
When installing avoid:
– very long venting systems
– too many bends or corners
– tight corners
otherwise the drying result will be less
effective and it will take longer and use
more energy.
Suitable materials for venting pipe-
work:
– galvanised steel piping
– plastic piping
– flexible piping
The venting connection can be made:
– to the rear (the machine is supplied
with the connection at the rear open)
– to the left or right side of the ma-
chine.
Install the venting pipework in such
a way that the moist expelled air
cannot be drawn into the machine
again.
Connection must not be made to a
flue used by gas or solid fuel boilers
or heaters.
Before installation, ensure that the
machine is not connected to the
electrical supply.
Installation - venting
Installation to the left or right side of
the machine
Remove only the cover cap. Do not
remove the frame.
Use the cover cap to close the rear
outlet.
Fitting the venting pipework
An adapter (Ø 100 mm) for the venting
pipe is supplied as standard.
It is to be fitted into the vent outlet to
facilitate connection of a flexible vent-
ing pipe.