  • Page 1 Operating and Installation Instructions ..........................Cooker Hoods DIA 1076-2 DIA 1076-2 EX DIA 1070-2 DIA 1070-2 EX...
  • Page 2 Contents ............2 .
  • Page 3 Caring for the environment The transport and protective packa- Old machines / appliances contain ma- ging has been selected from materials terials which can be reclaimed or re- which are environmentally friendly and cycled. Please contact your dealer, can normally be recycled. your waste collection centre or scrap merchant about potential recycling Rather than just throwing these ma-...
  • Page 4 Guide to the appliance...
  • Page 5 This control activates the run-on option. The fan is switched off automatically after either 5 or 15 minutes. The indicator lamp on the grease filter touch control lights up when the grease filter needs to be cleaned. The touch control is used –...
  • Page 6 Description of the functions The cooker hood works with The EX models of cooker hoods are de- signed to be connected with an The air is drawn in and cleaned by the The external fan is connected to the grease filter and directed outside. cooker hood by means of a control cable and is operated by the control panel on the cooker hood.
  • Page 7 Warning and Safety instructions system which complies with local and This appliance meets statutory national regulations. It is most import- safety requirements. Inappropriate ant that this basic safety requirement is use could however lead to risk of ac- tested by a qualified electrician. cidents to the user and damage to The manufacturer cannot be held re- the appliance.
  • Page 8 Always switch the cooker hood on terial. These can be obtained from the when a cooking zone is in use, Miele Spare Parts department or from otherwise condensation may collect in builders’ merchants. the hood, which could cause corrosion.
  • Page 9 When using the cooker hood at the same time as another heating ap- For appliances with an external fan pliance which depends on the air in the motor fitted (EX models) the connection room, (e.g. gas, oil or coal fired of the two units must be made using heaters, continuous flow or other water the connection cable and the plug con-...
  • Page 10 Operation When the main switch is set to “I” the cooker hood is ready for operation. When the cooker hood is switched off using the main switch, it will retain the – Use the touch control to select most recent setting when next switched the power level required.
  • Page 11 – Use the On/Off touch control to switch the fan off. The lighting for illuminating the hob can be switched on or off independently of the fan. – Press the lighting touch control. When it is switched on the lighting indi- cator lamp glows.
  • Page 12 An indicator lamp shows when the grease filter needs to be changed. The Before reaching the end of the period operating time counter for the grease fil- set, you can check the percentage of ter is set at the factory for a certain the time set which has already passed.
  • Page 13 – Use the On/Off touch control to switch the fan off. The operating time counter for the grease filter is set at 30 hours. This can be lengthened or shortened. You can choose from 20, 30, 40 or 50 hours. –...
  • Page 14 Cleaning and care Before any cleaning or maintenance work the cooker hood must be dis- A re-usable metal grease filter is fitted connected from the mains supply. which removes solid particles (oil, dust, Ensure that, depending on the con- etc.) from the kitchen vapours, prevent- nection, ing soiling of the cooker hood.
  • Page 15 Clean the filter – with a scrubbing brush in a mild solution of warm water and washing up liquid. – place the filter with the short side upright in the lower basket, ensuring the spray arm is not obstructed. Depending on the cleaning agent used, cleaning the grease filter in a dishwasher can cause permanent discolouration of the surface of the...
  • Page 16 Depending on the connection, dis- connect the cooker hood from the main supply by – switching it off at the fused unit, or – switching it off at the wall socket and removing the plug (do not pull on the cable, only on the plug), or –...
  • Page 17 After sales service In the event of any faults which you can- not remedy, please contact: – Your dealer – Your nearest Service Dept., (see ad- dress on back page). When contacting the Service depart- ment, please quote the Model and Ser- ial number of your appliance, both of which are given on the data plate which is visible on removing the grease...
  • Page 18 Electrical connection nal in the plug which is marked with the letter E or by the earth symbol z or col- All electrical work should only be under- oured green or green and yellow. taken by a suitably qualified and com- The wire which is coloured blue must petent person in strict accordance with be connected to the terminal which is...
  • Page 19 Installation Safety regulations prevent the fitting of this cooker hood over a solid fuel stove. The minimum safe distance be- tween the top of the cooker / hob and the bottom of the cooker hood should be at least: – 55 cm above electric cookers / hobs –...
  • Page 20 – Address the ceiling plate and posi- tion it exactly. Mark the position of – Drill four 10 mm ø holes in the ceiling the four holes to be drilled for se- and insert S10 plugs into the holes. curing the plate and the position for the gap for the mains cable If the cooker hood is to be con- nected to an external fan motor, also...
  • Page 21 – Assemble the tower. Place the flange plate of the tower onto the ceiling – Pull the mains connection cable plate in such a way that the spring through the ceiling plate. Screw the clips click into the slots securely. ceiling plate to the ceiling with the 8 x 60 mm screws and washers.
  • Page 22 – Shorten the cable for the electrical connection as much as possible and secure inside the cooker hood chim- ney with the cable clips. Ensure all safety regulations are complied with. – Finally, push the cover frame up- wards until the spring fixing clips click in securely and the frame lies tightly against the ceiling.
  • Page 23 – To do this tighten the 4 inner hexago- nal screws on each side. – To dismantle a glass panel hold the glass panel firmly and loosen the 4 inner hexagonal screws. – Pull the panel out of the housing to- wards the side.
  • Page 24 Installation - extraction – If the exhaust air is to be ducted into the open air the installation of a tele- scopic wall vent is recommended. Danger of toxic fumes. Please heed the “Warning and Safety instructions” to avoid the danger of toxic fumes.
  • Page 25 External fans The types of appliance available are listed in the table below. For further details please refer to the section on External Fans in the special book: Planning Informa- tion on Extractor Systems. Model: DV 1100 DV 1005/1 AWG 1100 ABLG 940/1 MG 1100 DV 1005/1G...
  • Page 26 External fan version plugs. Screw the housing together. Depending on the fan model involved, Position the interior telescopic part external fans can be installed on an out- and insert foam into the intervening side wall, on a pitched roof or in a suit- space.
  • Page 27 Technical data Rated load ....340 W Motor ....2 x 130W Lighting .