Alarm Functions - Toshiba JK-MX16A Instruction Manual

Color multiplexer
Table of Contents

Advertisement

3.5 High density Mode
Sets the multiplexer into high-density mode. When high-density mode is selected,
the multiplexer compresses two fields of information into one field thereby doubling
the refresh rate. While the refresh rate is improved when high-density mode is
enabled, there is a slight loss in image quality caused by image compression.
1 Normal
2 High density : High-density mode
Note: If the multiplexer is not set to 24 Hour or longer (SP) or 48 Hour or longer
(EP) in the Recording function menu, you can not set the High density
mode on it.
We recommend the multiplexer is used with the VCR time and date display
set to off.

4. Alarm Functions

4.1 Alarm Rec Priority
When an alarm signal is activated, camera priority recording can be programmed
from this menu.
1 Level 3: Only the camera that has an active alarm is recorded. All other cameras
are ignored for the duration of the alarm condition.
2 Level 2: The alarmed camera is recorded at a higher priority than non-alarmed
cameras (example: In a 4 camera system, when camera #4 is alarmed the
camera sequence would be as follows: 4,4,4,4,4,1,4,4,4,4,4,2,4,4,4,4,4,3).
3 Level 1: The alarmed camera is recorded at a higher priority than non-alarmed
cameras (example: In a 4 camera system, when camera #4 is alarmed
the camera sequence would be as follows: 4,4,4,1,4,4,4,2,4,4,4,3).
4 Level 0: No change to the recording sequence when an alarm is activated.
4.2 Alarm Input
Alarm Type
Sets the type of alarm input signal.
1 N.C : Normal Closed. When the contact is open, alarm will be set to operation.
2 N.O : Normal Open. When the contact is closed, alarm will be set to operation.
3 L.L : Logic Low. Alarm input in the logic "Low" level will sets the alarm operation.
4 L.H : Logic High. Alarm input in the logic "High" level will sets the alarm operation.
Main Mon Callout
When an alarm signal is activated, the main monitor displays the alarmed camera
channel. Each camera channel can be programmed independently.
1 Off
: Alarmed camera is not called out to main monitor.
2 On
: Alarmed camera is called out to main monitor.
3 Sche. : Alarmed camera is called out to main monitor based on a timer schedule.
Main Mon Display
Sets the display screen of the main monitor output when the alarm signal has been input.
1 Full : Full screen
2 2x2 : 2x2 screen
3 3x3 : 3x3 screen
4 4x4 : 4x4 screen
- 23 -
: Standard (normal) density mode
High density Mode
Normal
High density
:Set-up
MENU:Accept & Return
Alarm Functions
Alarm Rec Priority
Alarm Input
Motion Functions
Video loss
Alarm Event Log
:Select
ENTER:Next
MENU:Return
Alarm Rec Priority
Level: [ 3
]
[High
>>>>
Low]
:Set-up
MENU:Accept & Return
Alarm Input
Alarm Type
Main Mon Callout
Main Mon Display
Call Mon Callout
VCR Callout
Alarm Dwell time
Buzzer
:Select
ENTER:Next
MENU:Return