Download Print this page
Zoom 509 Modulator Operation Manual

Zoom 509 Modulator Operation Manual

Dual power modulator

Advertisement

Quick Links

Thank you for selecting the ZOOM 509 (hereafter simply called the "509").
Please take the time to read this manual carefully so you can get the most out of
your 509 and ensure optimum performance and reliability.
Retain this manual for future reference.
ZOOM CORPORATION
NOAH Bldg., 2-10-2, Miyanishi-cho, Fuchu-shi, Tokyo 183, Japan
PHONE: 0423-69-7116 FAX: 0423-69-7115
Major Features
1
• Dedicated modulation unit with two on-board modulation modules (EFFECT
1 and EFFECT 2) for a total of 20 effects. Up to two effects can be used
simultaneously, allowing versatile sound creations.
• Harmonized Pitch Shifter (HPS) lets you specify a desired key and scale to
create dual harmonies, a first in this price class. Do impressive guitar
orchestrations with twin or triple leads using a single instrument.
• You can switch between 24 patches to store diverse settings based on your
preference.
• Integrated auto-chromatic tuner for guitar. You can tune your instrument
easily anywhere, any time. You can also leave the tuning function disabled all
the time.
• DETECTOR IN jack for HPS pitch detection accepts the original guitar
signal, assuring reliable pitch shift action when used immediately after a
distortion effect.
• Optional expression pedal FP01 can be used to adjust pitch, effect mix level,
output level and other parameters. Optional foot switch FS01 lets you switch
EFFECT 1 on and off during a performance.
• Dual power supply design allows the unit to be powered from a 9V alkaline
battery (6LR61) or an AC adapter.

Safety Precautions

2
USAGE AND SAFETY PRECAUTIONS
In this manual, symbols are used to highlight warnings and
cautions for you to read so that accidents can be prevented. The
meanings of these symbols are as follows:
This symbol indicates explanations about extremely
dangerous issues. If users ignore this symbol and handle
the device incorrectly, serious injury or death could
Warning
result.
This symbol indicates explanations about dangerous
issues. If users ignore this symbol and handle the
device the wrong way, bodily injury and damage to the
Caution
equipment could result.
Please observe the following safety tips and precautions to ensure
hazard-free use of the 509.
About power
Warning
Since power consumption of this unit is fairly high, we
recommend the use of an AC adapter whenever possible.
When powering the unit from a battery, use only an alkaline
type.
AC adapter operation
• Be sure to use only an AC adapter which supplies 9 V DC,
300 mA and is equipped with a "center minus" plug (Zoom
AD-0006). The use of an adapter other than the specified type
may damage the unit and pose a safety hazard.
• Connect the AC adapter only to an AC outlet that supplies the
rated voltage required by the adapter.
• When disconnecting the AC adapter from the AC outlet,
always grasp the adapter itself and do not pull the cable.
• If the unit is not to be used for a long time, disconnect the AC
adapter from the outlet.
Battery operation
• Use only a 9 V (alkaline) battery (6LR61).
• The 509 cannot be used for recharging.
Pay close attention to the labelling of the battery to make sure
you choose the correct type.
• If the 509 is not to be used for an extended period of time,
remove the battery from the unit.
• If battery leakage has occurred, wipe the battery compartment
and the battery terminals carefully to remove all remnants of
battery fluid.
• While using the unit, the battery compartment cover should
be closed.
Environment
Caution
Avoid using your 509 in environments where it will be
exposed to:
• Extreme temperature
• High humidity or moisture
• Excessive dust or sand
• Excessive vibration or shock
Handling
Caution
• The 509 is a precision instrument. Except for the foot
switches, do not push other parts with your feet or subject
them to strong force.
• Take care that no foreign objects (coins or pins etc.) or liquids
enter the unit.
• Be sure to turn the power to all equipment off before making
connections.
• Before moving the unit, turn the power off and disconnect all
cables and the AC adapter.
Alterations
Caution
Never open the case of the 509 or attempt to modify the
product in any way since this can result in damage to the unit.
Operation Manual
Printed in Japan 509-5000
Usage precautions
Electrical interference
For safety considerations, the 509 has been designed to provide
maximum protection against the emission of electromagnetic
radiation from inside the device, and from external
interference.However, equipment that is very susceptible to
interference or that emits powerful electromagnetic waves
should not be placed near the 509, as the possibility of
interference cannot be ruled out entirely.
Whatever the type of digital control device, the 509 included,
electromagnetic damage can cause malfunctioning and corrupt
or destroy data. Since this is an ever-present danger, thorough
care should be taken to minimize the risk of damage.
Cleaning
Use a soft, dry cloth to clean the 509. If necessary, slightly
moisten the cloth. Do not use abrasive cleanser, wax, or
solvents (such as paint thinner or cleaning alcohol), since these
may dull the finish or damage the surface.
Connecting cables and input and output jacks
You should always turn off the power to the 509 and all other
equipment before connecting or disconnecting any cables. Also
make sure to disconnect all cables and the AC adapter before
moving the 509.

Advertisement

loading

Summary of Contents for Zoom 509 Modulator

  • Page 1: Safety Precautions

    Operation Manual Thank you for selecting the ZOOM 509 (hereafter simply called the "509"). Please take the time to read this manual carefully so you can get the most out of your 509 and ensure optimum performance and reliability. Retain this manual for future reference.
  • Page 2: Selecting Patches

    Selecting Patches Bank switching Banks A, b, C, d, E, F are available BANK F PATCH PATCH PATCH 1 DOWN PATCH 2 PATCH 3 Patch switching PATCH 4 24 patches are available BANK E PATCH 1 PATCH 2 The 24 patches can be easily selected by PATCH 3 pressing the patch pedals.
  • Page 3: Patch List

    OUTPUT jack DIRECT OUT DETECTOR IN adapter (Zoom AD-0006) which This jack is for the output signal from the 509. You can connect either a single delivers 9 VDC, 300 mA with a guitar amplifier, using a monaural shielded cable, or two guitar amplifiers, using NOTE "center minus"...
  • Page 4: Effect Parameters

    Editing Patches The 509 comes with 24 predefined patches. However, the 509 offers many more possibilities for In Edit mode, the EDIT key or the PATCH UP/DOWN pedals serve to select the parameter. Each push of the EDIT key moves the blinking parameter cursor one step down. The PATCH combining effects in innovative ways.
  • Page 5: Storing Patches

    For optional FP01 or FS01 Display: 2-digit, 7-segment LED, tuning indicator, parameter cursor indicator Power Requirements: Optional AC adapter 9 VDC, 300 mA (Zoom AD-0006) Battery: 6LR61 9 V (alkaline) battery x 1 Battery life: Approx. 4 h continuous operation Dimensions:...
  • Page 6 Patch Switching (Application: Bank Hold ON) In the initial setting, the patch pedal switches all patches in order, regardless of the bank divisions. Bank Hold ON Keeping the EDIT key depressed for at least 1 second activates Bank Hold. To cancel Bank Hold, press the EDIT key again for 1 second. The bank hold function limits switching to the four patches within a bank.