SLEEVE AND MANIFOLD INSTALLATION

METHOD FOR STANDARD WALLS
1. Disassemble Manifold from Sleeve.
The flue consists of 3 parts, sleeve, inside connectors
and tube, outside terminal; (dis-assembly by pulling
hard on outside terminal and inner connections, then
pull sleeve off outer terminal.)
NOTE: Clearance to combustibles for terminal
assembly sleeve and flanges is 0".
2. Adjustment of Sleeve Length.
Measure wall thickness through previously drilled 3 1/8
(80mm) hole.
End of sleeve should protrude 3/16" 3/8" (5 10mm)
from outside wall. Adjust sleeve length to wall
thickness plus 3/16" 3/8" (5 10mm). (Sleeve is
threaded for adjustment.) Do not extend beyond red
line.
3. For S and A flue only.
Depending on flue set and wall thickness extension
piece "C" may need to be removed.
Cut plastic, remove extension, then follow instruction 2.
This applies to "S" and "A" flues only.
There is no extension on other flues, they can be fully
adjusted by turning the threaded section.
4. Fixing Sleeve.
Fix to the wall, using the 3 screws provided.
NOTE: The flange is marked "TOP", sleeve must be
fitted with this mark Up. Check sleeve protrudes 3/16"
3/8" (5 10mm) on the outside.
Connection
Do not extend
beyond red line
Extension joint
under plastic
Adjust length by turning sleeve.
A
"A" Flue only
"TOP"
Fixing Screw
Don't remove green plastic covering from sleeve.
– 20 –
Flanges
Sleeve
Terminal
Extension
("S" and "A" flues only)
B
C
Remove extension at this
point it necessary.
5-10mm