Installation; Statutory Regulations; Australia Specific Clause; Siting - Garland G24 SERIES Installation And Service Manual

G24 series gas-operated counter griddle
Table of Contents

Advertisement

INSTALLATION

Statutory Regulations

The installation of this appliance must be carried out by
a competent person and in accordance with the relevant
regulations, standards, codes of practice and the related
publications of the Country of destination . Failure to install
appliances correctly can lead to prosecution . It is in your own
interests and that of safety to insure that there is compliance
with the law .

Australia Specific Clause

This appliance must be installed in accordance with the
manufacturers instructions, local gas fitting regulations
and requirements of AS 5601 / AG 601 installation code .
All burner adjustments and settings should be made by a
qualified gas technician .

Siting

The base on which the unit is to be sited must be firm,
smooth and capable of adequately supporting the weight of
the appliance and any ancillary equipment . ( Refer to table
A for weight specifications ) . Once in position check that
the unit is level, both front to back and side to side . Adjust if
necessary using the leveling feet on the four corners of the
legs fitted . Any openings in the wall behind or beside the
appliance must be sealed .

Clearances

The space in which the appliance is to be sited must include
the minimum installation clearances to combustible surfaces .
Minimum Installation Clearances
To Adjacent Combustable Walls
- All Models
Sides
Back
Type Of Floor Or Base
Non Combustible or Combustible
with 2" (51mm) legs
Page 8
6" (152mm)
6" (152mm)

Ventilation Air

The area in which the appliance is installed must be
adequately ventilated to provide air for combustion, removal
of products of combustion, etc . The use of a mechanical
extract system should be considered .
The following notes are intended to give general guidance .
For detailed recommendations, refer to the applicable
code(s) in the Country of destination .
Note 1: The room containing the appliance is required to
have a permanent air vent . The minimum effective area of
the vent is related to the maximum rated heat input of the
appliance and shall be4 .5 cm
Note 2: Air vents should be of such a size to compensate for
the effects of any extract fan in the premises .

Gas Connection

The gas pipe connection is made at the left hand side of
the equipment . The size of the pipe work supplying the
appliance must not be less than the inlet connection which is
ISO 7/R 3/4" . After installation, the complete pipe work must
be checked for soundness .

Gas Supply

The local gas region should be consulted at the installation
planning stage in order to establish the availability of an
adequate supply of gas and to ensure that the meter is
adequate for the required flow rate . The pipe work from
the meter to the appliances must be of an appropriate size .
Where a number of appliances are installed in a battery, no
more than five should be served by any one supply pipe .
All fixed ( non mobile ) appliances MUST be fitted with a
manual gas cock upstream of the appliance to provide a
means of isolation for servicing or cleaning purposes . A
union or similar means of disconnection must be provided
between the gas cock and the appliance .
A manually operable valve must be fitted to the gas supply
to the kitchen to enable it to be isolated in an emergency .
Wherever practical, this shall be located either outside the
kitchen or near to an exit in a readily accessible position .
2
per kW in excess of 7 kW .
Part # 4521357 (12/07)