Heating System - Sears 1F80-382 Installation And Operation Instructions Manual

Programmable electronic digital thermostat
Table of Contents

Advertisement

JUMPER
WIRE
attacln to RH and W
J
TRANSFORMER
Figure 2.Typical wiring diagram for
heat only, 3-wire, single transformer
systems
JUMPER
WiRE
TRANSFORMER
Figure 3. Typical wiring diagram for
cool only, 3-wire, single transformer
systems
RED jumper wire (provided
with thermostat)
must be
_connected
between thermostat
RR and RC terminals_
JUMPER
_for proper thermostat
operation with this system.
_
WIRE
T
o
TRANSFORMER
Figure 4. Typical wiring diagram for
heat/cool, 4=wire, single transformer
systems
v
_)24_SYSTE:°t
l
_
Neutral
a
TRANSFORMER
24vAc L I 14.120wc
'==L_
Neutral
COOLING
TRANSFORMER
Figure &Typical
wiring
diagram for
heat/cool, 5-wire, two-transformer
systems
JUMPER
JUMPER
WIRE
WIRE
I
_1
Contactor |U
L____
_
!
!
L
24VAC
U
_C
* Reversing
valve is energized
when tlne
_=J_Neutral
system switch is in the COOL position
TRANSFORMER
Figure 6. Typical wiring diagram for heat pump
with reversing
valve energized
in COOL
* Reversing
valve is energized
when the
system switch is in the HEAT position
JUMPER
JUMPER
WIRE
WIRE
T
)mpressorll
t-an I
I
;°ntact°r
! Re[_
1
24 w c
TRANSFORMER
Figure 7.Typical
wiring diagram
for heat pump
with reversing
valve energized
in HEAT
* The 24 Volt neutral connection to terminal C on the thermostat is not required if the batteries are replaced once a year
with fresh premium brand alkaline batteries.
Heating System
1. Move SYSTEM switch to HEAT position.
If the heating
system has a standing pilot, be sure to light it.
2. Press (_
to adjust thermostat setting above room tempera-
ture. The heating system should begin to operate.
3. Press (_
to adjust temperature
setting below room tem-
perature. The heating system should stop operating.
Cooling
System
To prevent compressor and/or property damage,
if the
outdoor temperature
is below 50°F, DO NOT operate
the cooling system.
1. Move SYSTEM switch to COOL position.
2. Press (_) to adjust thermostat setting below room tempera-
ture. The blower should
come on immediately
on high
speed, followed by cold air circulation
3. Press (_
to adjust temperature
setting above room tem-
perature. The cooling system should stop operating.

Hide quick links: