C. 240VAC Hardwire Installation
•
Turn off circuit breaker.
•
Access knockout.
•
Remove the access cover plate.
•
Disconnect the power cord from the terminal block.
•
Remove the knockout and install the cable clamp (not
provided) into the hole.
•
Feed 8 in. of service wire through the cable clamp and
secure.
•
Connect the black wire from the service to the L1
terminal.
•
Connect the red wire from the service to the L2
terminal.
•
Connect the white wire from the service to the N
terminal.
•
Connect the green (ground) from the service to the GND
terminal.
•
Optional wall switch wiring is to be done at this time.
•
Replace access cover plate.
LAMP
PE
N
L1
120 V
L2
TERMINAL STRIP
120 VAC PLUG OR 120/240
HARD WIRED
Figure 4.1
120V/240V Wiring Diagram
10
Heat & Glo • CRESTFIRE Series Electric Fireplace • 4030-781 Rev F • 10/06
LAMP
FLAME M0TOR
120 VAC
LAMPS
-12VDC
DIMMER
B
-
+
A
12VDC
SUPPLY
120 V
240 V
120VAC - 240VAC 60 HZ SPLIT-PHASE
D. Wall Switch Wiring (12VDC)
*Do not connect wires to 120/240VAC*
ers only)
•
Turn off circuit breaker.
•
Access knockout.
•
Remove the access cover plate.
•
Feed 16 in. of service wire through the cable clamp and
secure.
•
Low voltage wire can be used for the wall switch
connection.
•
Locate the loop of blue wire on the accessory
connector.
•
Cut the loop and connect one side to one of the wall switch
wires and the other side to the other wire for the switch.
•
Replace the access cover plate.
•
Run the wall switch wire to the wall box and connect to a
wall switch (WSK-21 & WSK-21-W).
R2
SPEED
CONTROL
OPTIONAL
REMOTE HEAT
REMOTE OR
CONTROL
WALL ON/OFF
SWITCH
BLOWER
WHITE
POWER
BLACK
-12VDC
RED
3 PIN WIRING
HARNESS
B
A
THERMOSTAT
RELAY
D1
DIODE
HEAT SWITCH
BLOWER
120 VAC
HIGH LIMIT
HIGH LIMIT
HEATER 1
BLACK
RED
POWER NEUTRAL MUST NOT
CONNECT TO VIRTUAL NEUTRAL
OF HEATERS OR BLOWER IN
240VAC VERSION
(hardwired heat-
BLOWER
HEATER 1
240 VAC
HEATER 2