Harbor Freight Tools 43149 Set Up And Operating Instructions Manual

Advertisement

Metal Detector

Set up anD operating inStructionS
Distributed exclusively by Harbor Freight tools
Visit our website at: http://www.harborfreight.com
read this material before using this product.
Failure to do so can result in serious injury.
SaVe tHiS Manual.
Copyright
2000 by Harbor Freight Tools
©
or any artwork contained herein may be reproduced in any shape or form without the
express written consent of Harbor Freight Tools. Diagrams within this manual may not be
drawn proportionally. Due to continuing improvements, actual product may differ slightly
from the product described herein. Tools required for assembly and service may not be
included.
For technical questions or replacement parts, please call 1-800-444-3353.
3491 Mission Oaks Blvd., Camarillo, CA 93011
43149
. All rights reserved. No portion of this manual
®
.
®
Manual revised 09c

Advertisement

Table of Contents
loading

Summary of Contents for Harbor Freight Tools 43149

  • Page 1: Metal Detector

    Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein.
  • Page 2: Specifications

    Do not oper- detector may discover underground ate any tool when you are tired. power lines, explosives or other items which when struck could cause per- SKU 43149 For technical questions, please call 1-800-444-3353. Page 2...
  • Page 3: Preparing To Operate

    1/2 to 2 inches this product will expose you to lead, above the ground (see Figure 2). a chemical known to the State of California to cause cancer, and birth reV 07f; 09c SKU 43149 For technical questions, please call 1-800-444-3353. Page 3...
  • Page 4: Battery Installation

    Place one 9 Volt bat- the plug and pull it out of the connec- tery into the battery tor. compartment on top of the ribbon. Place Figure 7 SKU 43149 For technical questions, please call 1-800-444-3353. Page 4...
  • Page 5: Meter Adjustment

    (see Figure 11). testing Batteries Test the battery power when the Tool does not turn on, or has weak volume, or will not tune properly or operates errati- cally. SKU 43149 For technical questions, please call 1-800-444-3353. Page 5...
  • Page 6: Basic Operation

    Rotate VoluMe to the 10 o’clock tector might sound a tone. The reaction position. depends on what metal is detected. MoDe to VlF. SKU 43149 For technical questions, please call 1-800-444-3353. Page 6...
  • Page 7: Testing The Tool

    Sweep in a side to side mo- After removing watches, rings or any tion as follows: other metal jewelry, place the de- tector on a wooden or plastic table. Adjust the search coil’s angle so that SKU 43149 For technical questions, please call 1-800-444-3353. Page 7...
  • Page 8: Fine Tuning

    Repeat these three steps until the pointer stays close to the center each time you lower the search coil to the ground. SKU 43149 For technical questions, please call 1-800-444-3353. Page 8...
  • Page 9: Troubleshooting

    If target is heavily oxidized, an incorrect reading may occur. This does correct metal type not signify a problem with the detector. It may be a type of metal which is not recognizable to the detector. SKU 43149 For technical questions, please call 1-800-444-3353. Page 9...
  • Page 10: Parts List

    Some parts are listed and shown for illustration purposes only and are not avail- able individually as replacement parts. Warning! Service and maintenance should only be performed by a qualified technician. SKU 43149 For technical questions, please call 1-800-444-3353. Page 10...
  • Page 11: Parts Diagram

    DiagraM SKU 43149 For technical questions, please call 1-800-444-3353. Page 11...

Table of Contents