Firex FADCQ Manual page 17

Smoke/carbon monoxide alarm
Hide thumbs Also See for FADCQ:
Table of Contents

Advertisement

Understanding the Alarm LEDs and Horn Patterns
CONDITION
AC power is present
Standby condition
Standby condition
Low-battery #1
Low-battery #2
Fault condition
Local smoke
is detected
Local smoke condition
is latched
Quick Quiet™ False
Alarm Control™
is activated
Local CO is detected
Local CO condition
is memorized
CO Reset is activated
Remote signal is
received from another
smoke or heat alarm
Remote signal is
received from another
CO alarm
HORN
Horn beeps once
per minute
Horn beeps once
per minute
Horn beeps 2 times
per minute
Horn sounds 3 long
tones, then pauses,
every 4 seconds
Horn sounds 4 short
tone pattern every
5 seconds
Horn sounds 3 long
tones, then pauses,
every 4 seconds
Horn sounds 4 short
tone pattern every
5 seconds
LEDs
Green light ON
Red and Blue blink
once per minute
Red and Blue blink
once per minute
Yellow light flashes 5
times per minute after
horn beeps
Yellow light flashes 7
times per minute after
horn beeps
Yellow light flashes 2
times per minute after
horn beeps
Red-Yellow-Orange
lights flash with horn
Red light flashes 3
times every 10 seconds
Red light flashes 1
time every 10 seconds
Blue light flashes 4
times right after horn
Blue light flashes 4
times every 10 seconds
Blue light flashes 1
time every 10 seconds
17
SMART BUTTON KEY
Quick push activates False Alarm Control
and a longer press also activates a local
Push-to-Test sequence.
Press and hold until the double chirp to
activate a local Push-to-Test sequence and
send a signal to other interconnected alarms.
Quick press will eliminate the low-battery
signal for about 8 hours.
Smart button inoperable.
Replace battery immediately.
Press and hold to check the alarm again.
Replace alarm if it remains in fault
condition.
Quick press activates False Alarm
Control
TM
.
Quick press releases the latched LED.
Quick press activates CO Reset.
Quick press erases the CO memory signal.
Quick press activates Smart Quiet™ Trigger
Alarm Locator for smoke and heat alarms.
Quick press activates Smart Quiet™ Trigger
Alarm Locator for other Model FADCQ
combination smoke-CO alarms.
TM

Advertisement