Attaching the emitter to the IR sensor window
First decide if the CUT-IR will be blocking (does not permit other
infrared signals to be read by the component receiver) or non-
blocking to other infrared signals on the controlled device.
The bendable CUT-IR shell does not allow other infrared signals
to pass through it.
If it is to be non-blocking; use a pair of scissors to cut down the
size of the emitter as desired. Thin guide lines are etched into
the CUT-IR surface so that the emitter can be cut square. Be
careful not to cut the wires or components on the emitter.
Locate the IR sensor window on the component and test that
the emitter is in the correct position before removing the
emitters adhesive layer protector. In some cases it may be
difficult to find the location of the component IR sensor. Consult
the owners manual or manufacturer if this location is not readily
apparent.
Once the IR sensor window is located and emitter has been
tested, remove the emitters adhesive cover and affix the CUT-IR
with its underside emitter leds positioned to the center of the
component to be controlled IR sensor window. The CUT-IR can
be bent around uneven surfaces and will continue to stick
perfectly.
Connecting the CUT-IR
Simply insert the mono 3.5mm mini plug of the CUT-IR into any
of the "EMITTERS" jacks on a Knoll Systems connecting block
such as the IR55.
CAUTION: Never connect the CUT-IR directly to a power supply
as it will instantly destroy the emitter and there is no visual
indication that it has been destroyed. If it still works it can be
tested with a common diode checker.
If you are more technically advanced and need to do so, the
yellow plug can be snipped off and the wires directly connected
without a connection block. The wire with the white stripe is
positive.
If you have any questions or concerns, please call the Knoll
Systems technical support at 1 800 566 5579. Technical support
is available from 6:30 a.m. to 4:30 p.m., Monday to Friday,
Pacific time.
IR230
P anel
n ut
Bezel
Wh ite
Wire
IR55
12V
IR230
GND
SI G
Whi te
W ire
Connection
Block
Note: IR230's are
wired in parallel
PS1205
12 V DC Power Supply
R ece iv e r
CU T-IR show n block in g
CD
CUT -IR sh own
non-b lo cking
TYPICAL INSTALLATION