Summary of Contents for FieldServer Canatal Satchnet Driver FS-8700-59
Page 1
Driver Manual (Supplement to the FieldServer Instruction Manual) FS-8700-59 Canatal Satchnet Driver APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after November 2011 A Sierra Monitor Company Driver Version: 1.02 Document Revision:...
CANATAL SATCHNET PROTOCOL DRIVER DESCRIPTION The Canatal Satchnet Protocol Driver allows the FieldServer to transfer data to and from devices over either RS-232 or RS-485 using Canatal Satchnet Protocol Driver protocol. The FieldServer can emulate either a Server or Client.
100 ohms to frequencies greater than 100 kilohertz and a DC series loop resistance not exceeding 240 ohms. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 5 of 19...
This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a Canatal Satchnet Client. The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for Canatal Satchnet Protocol Driver communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction manual for details of the ports available on specific hardware. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com , Port , Cana_Node_Protocol_Type...
Scan_Interval Rate at which data is polled FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Legal Values Up to 32 alphanumeric characters...
FLOAT and should have at least 1 element in size. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com Page 10 of 19 , Function...
This section documents and describes the parameters necessary for configuring the FieldServer to communicate with a Canatal Satchnet Server. The configuration file tells the FieldServer about its interfaces, and the routing of data required. In order to enable the FieldServer for (Driver Name) communications, the driver independent FieldServer buffers need to be declared in the “Data Arrays”...
FS-8700-59 Canatal Driver Manual 6.3.4 Map Descriptor Example In this example the FieldServer is emulating a Canatal device addressed as node 11. It is not possible to have the FieldServer emulate two devices of different series addressed as node 11.