Mounting location diagrams spill switch mounting location on an mg-1 4” – 9” barometric draft control (2 pages)
Summary of Contents for Field Controls Gas Spillage Sensing Kit GSK-250M
Page 1
GAS SPILLAGE SENSING KIT Installation of a spillage SAFETY Switch is recommended for LP and Natural gas fired systems with draft hoods, draft diverter, or gas barometric draft controls. This device is installed to detect flue gas spillage caused by a blocked flue system and/or inadequate draft. This device MUST be installed by a qualified installer in accordance with the manufacturer's installation instructions.
Page 2
2 1/2 inches from the opposite ends and sides of the draft hood opening. (See Figure 1) 2. The switch should not contact the metal. They should be mounted at least 3/4 inch below the hood opening. (See Figure 2) Mount with supplied sheet metal screw.
Page 3
(See Figure 8) 3. Swing the gate to make sure the gate does not hit the screw head or the switch. NOTE: Mounting the spill switch on the top of the draft control ring will function properly, but will react slower during a blocked flue condition.
Page 4
3. Mount the two (2) spill switches onto the draft hood so the switches do not contact any metal. (See Figure 13) 4. Connect the one terminal of each switch with 12 ga wire and then connect it to the thermocouple junction block. Next,connect the two remaining terminals together using a short length of 12 ga wire.