Tools Needed - Whirlpool GT1SHTXMQ04 Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

Emectrica_ Shock Hazard
Pmuginto a grounded
3 prong outleto
Do not remove ground prong,
Do not use an adapter,
Do not use an extension
cord.
FaiJure to follow these }nstructions
can resumt }n death,
fire, or electrical
shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended
Grounding
Method
A 115 Volt, 60 Hz., AC only 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, turn the control (Thermostat, Refrigerator or
Freezer Control depending on the model) to OFF and then
disconnect the refrigerator from the electrical source. When you
are finished, reconnect the refrigerator to the electrical source and
reset the control (Thermostat, Refrigerator or Freezer Control
depending on the model) to the desired setting.
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
TOOLS NEEDED:
Flat-blade screwdriver
1/411 Drill bit
7/1611
and 1/211 open-end or two
Hand drill or electric drill
adjustable wrenches
(properly grounded)
1/411 nut driver
NOTE: Your refrigerator dealer has a kit available with a %"
(6.35 mm) saddle-type shutoff valve, a union, and copper tubing.
Before purchasing, make sure a saddle-type
valve complies with
your local plumbing codes. Do not use a piercing-type
or 3/lO"
(4.76 mm) saddle valve which reduces water flow and clogs more
easily.
IMPORTANT:
All installations must meet local plumbing code requirements.
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures
will remain
above freezing.
Water Pressure
A cold water supply with water pressure of between 30 and
120 psi (207 and 827 kPa) is required to operate the water
dispenser and ice maker. If you have questions about your water
pressure, call a licensed, qualified plumber.
Reverse Osmosis
Water Supply
IMPORTANT:
The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 30 and 120 psi (207 and
827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If your refrigerator has a water filter, it may further reduce the
water pressure when used in conjunction
with a reverse
osmosis system. Remove the water filter. See "Water Filtration
System."
If you have questions about your water pressure, call a licensed,
qualified plumber.
Read all directions before you begin.
IMPORTANT: If you turn the refrigerator on before the water line is
connected, turn the ice maker OFR
Connect to Water Line
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long
enough to clear line of water.
3. Locate a 1/2"to 11/4 '' (1.25 cm to 3.18 cm) vertical cold water
pipe near the refrigerator.
IMPORTANT:
4.
5.
Make sure it is a cold water pipe.
Horizontal pipe will work, but drill on the top side of the
pipe, not the bottom. This will help keep water away from
the drill and normal sediment from collecting in the valve.
Determine the length of copper tubing you need. Measure
from the connection on the lower left rear of refrigerator to the
water pipe. Add 7 ft. (2.1 m) to allow for cleaning. Use 1/4"
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure both
ends of copper tubing are cut square.
Using a grounded drill, drill a 1/4"hole in the cold water pipe
you have selected.
........ A
G
......... ................
B
....... .......
C
A. Cold water pipe
E. Compression sleeve
B. Pipe clamp
F. Shutoff valve
C. Copper tubing
G.Packing nut
D. Compression nut

Advertisement