Pedestal Mount; Internal Factory Wiring - Riello 40 F5 Installation & Operating Manual

40 series residential oil burners, equipped with electronic air shutter
Table of Contents

Advertisement

METHOD
3 - PEDESTAL
MOUNT
Secure the MOU2,,!T1NGFLANGE to MOUE'qT1NGPEDESTAL using the hardware provided with the pedestal.
Secure burner to MOU2,,!T1NG FLANGE as in METHOD 1, item A, C and D.
NOTE:
It is suggested
that the pedestal be anchored
in position on the floor by installing brackets over the
pedestal tube and securing brackets to the floor.
WARNING:
WHEN
THE
COMBUSTION
CHAMBER
IS
LINED
WITH
A
REFRACTORY
MATERIAL,
IT IS
IMPERATIVE
THAT
THE
END
CONE
NOT
PROTRUDE
INTO
THE
CHAMBER
AREA,
AS EXCESSIVE
HEAT
AT
BURNER
SHUT DOWN MAY DAMAGE
THE END CONE.
INTERNAL
FACTORY
WIRING
RIELLO
40 F SERIES
OIL BURNERS
EQUIPPED
WITH AN ELECTRONIC
AIR SHUTTER
INTERNAL
FACTORY
WIRING
PUMP
VALVE
(COIL)
A-
D
I--
C
D
aK
CAPA(ITOR
r-tl--
SEE FIELD
___
WIRING
LEGEND:
(A)
BROWN
(B)
WHITE
(C)
BLUE
(D)
BLACK
(6)
120V SOURCE
ACTIVATES
SHUTTER
OPEN
(11)
MOTOR
LEAD 120V SOURCE
(®)
120V CONTROL
LOCK
OUT ALARM
TERMINAL
(AUX)
CONSTANT
120V AUXILIARY
TERMINAL
- ELECTRONIC
AIR SHUTTER
Standard
40 F3-F5 I-O manual Rev4
l.doc
Page 8 of 8