Riello 40 F5 Installation & Operating Manual page 6

40 series residential oil burners, equipped with electronic air shutter
Table of Contents

Advertisement

ASSEMBLY
OF AIR TUBE
TO BURNER
CHASSIS
The air tube and drawer assembly are shipped in a carton separate from the burner chassis. Choose the proper
air tube length to obtain the tube insertion for the specific installation.
A) Remove the AIR TUBE and BURNER CHASSIS from theft respective cartons.
B) Remove the DRAWER
ASSEMBLY
(1) from inside the MR
TUBE by loosening the screw (2). Carefully
pull the DRAWER
ASSEMBLY
out of the AIR TUBE, install the required nozzle (see page 8) and set
aside.
C) Remove the two BOLTS (3) from FRONT PLATE (4) of the BURNER
CHASSIS. Align the two holes on
the MR
TUBE HOLD1NG PATE (5) with the two holes on the BUNNER
CHASSIS FRONT PLATE with
the BOLTS (3) removed.
Replace the BOLTS
and fingers tighten only. Re-install DRAWER
ASSEMBLY
into AIR TUBE. Tighten SCREW (2) securely (see page 8).
D) Tighten the two bolts (3) securely.
®
:
t
MOUNTING
THE
BURNER
TO THE
BOILER
OR FURNACE
There are three possible methods to mount the burner, depending on the individual application. These are:
1) Universal flange bolted to Boiler2umace
unit.
2)
Semi-flange collar bolted to Boiler2urnace
unit.
3) Universal
flange mounted
to optional Pedestal
mount, where
flange mounting
direct to appliance
is not
possible. Pedestal kit must be ordered separately.
Standard
40 F3-F5 I-O manual
Rev4
l.doc
Page 6 of 6