4.
Review the Exhausting
section before installing
the exhaust system.
Install the ductwork
from your dryer
to the exhaust hood. The crimped
end of the duct sections
must point away from your dryer.
DO NOT use sheet metal screws when assembling
ducting.
These joints should
be taped.
Never
use plastic
flexible
exhaust
material.
Tip for tight installations:
install a section of exhaust system to your dryer before putting it in place.
Use duct tape to secure this section to your dryer, but do not cover ventilation
slots at the back of the
unit in the dryer cabinet.
5.
Review Electrical
Requirements
section.
BEFORE
OPERATING
OR TESTING,
follow the grounding
instructions
in the Grounding
section.
U.S. MODELS:
IMPORTANT
-All
U.S. models
are produced
for a 3-WIRE
SYSTEM
CONNECTION.
The Dryer frame is grounded
to the neutral conductor
at the terminal
block.
A 4-WIRE
SYSTEM
CONNECTION
is required for new or remodeled
construction,
mobile
homes,
or if local codes do not permit
grounding
through
neutral conductor.
If the 4-wire system
is used, the Dryer frame cannot
be grounded
to the neutral conductor
at the terminal
block.
Refer to the following
instructions
for 3- and 4-WIRE SYSTEM
CONNECTIONS.
Remove the terminal block cover plate.
Insert the power cord with a UL-listed
strain relief through
the hole provided
in the cabinet
near the
terminal
block.
[_A
strain relief must be used.
Do not loosen the nuts already installed on the terminal
block.
Be sure they are tight.
Use a 3/8" (1cm) deep well socket.
Review Gas Requirements
section.
Remove the pipe thread
protective
cap.
Apply pipe joint compound
or about 1 1/2 wraps of Teflon tape over all threaded
connections.
(_
Pipe joint compound
must be resistant to the action of any liquefied
petroleum
gas.
Connect
the gas supply to your Dryer.
An additional
fitting is required to connect
the 3/4" (1.9 cm) female thread end of a flexible connector
to
the 3/8" (1 cm) male threaded
end on the dryer.
Securely tighten the gas line fitting over threads.
Turn on the gas supply. Check all gas connections
for leaks using a soap solution.
If bubbles appear, tighten the connections
and recheck.
DO NOT use an open flame to check for gas leaks.
16 installing your dryer