Refrigerant Recharging - LG GR-382R Service Manual

Hide thumbs Also See for GR-382R:
Table of Contents

Advertisement

Service Precautions
Refrigerant
Recharging
Test the compressor's
operation
before
recharging
the refrigerant;
this is very
important
to detect failures and to
ensure the proper motor running, and
to identify failures immediately.
If
failure has been detected,
clean the
system from any other possible
R-134a residues
by breaking
the final
part of the compressor's
service pipe
at it's thinnest
part as shown in Fig. #1.
Replace the filter and any other part
that could be deteriorated.
Unweld
and pull out the service pipe,
then place a new pipe extension
with a
Hansen male connector
and solder
the new pipe. See Fig. #2
POINTTO BE
BROKEN
CHARGETUBE
EX?ENSiON
MALE HANiSEN
SERVICE T UNE EXTENSION
SOLDNRFNG
POINT
Figure 1i
Fig;ute 2
It is necessary
to open the valve
when soldering
to allow the gases to
escape without forcing the molten
solder out of the joint. The extension
with the male Hansen connector
should be connected
to a female type
connector
to the vacuum
pump's pipe.
See Fig. #3
System air evacuation
starts as soon
as the pump begins to run. The
system must be kept under vacuum
until the low pressure gauge shows
0(absolute
or -1 atm, -760 mm Hg.) It
is not recommend
to run the vacuum
pump for more than 30 minutes. See
Figure 3.
In case there is a large leak and the
vacuum operation
must stop,
you must add a small amount of
refrigerant
to the system and check
with an electronic
leak detector.
If a
soldering
failure is detected,
open the
valve before soldering to equalize
the
pressure
and keep solder from being
blown out of the joint or sucked into
the piping.
As soon as the repair is completed,
charge the correct amount
of
refrigerant
into the system.
Remember
that each system requires
a specific
amount of refrigerant
with a
tolerance
of +5 grams. See Figure 4.
TO THE b_ 134_ CYLliH_R
_3ySTE_
I_igur_
" 4
Before performing
this operation
(if
the vacuum
pump and charging
cylinder
are still attached
to the
system)
be sure the valve between
the pump and the cylinder
is closed to