LG GR-051SF Servicing Precautions
Hide thumbs Also See for GR-051SF:

Advertisement

Quick Links

SAFETY PRECAUTIONS
Please read the followings before servicing your refrigerator.
1. Check if an electric leakage occurs in the set.
2. When servicing current applying parts, unplug prior to
servicing.
3. In case of testing with power injecting, wear rubber
gloves to prevent electric shock.
4. If you use any appliances, check regular current, voltage
and capacity.
5. Don't touch metal products in cold freezer room with wet
hand. It may cause frostbite.
6. Prevent water flowing to electric elements in mechanical
parts.
7. When sloping the set, remove any materials on the set,
especially thin plate type(ex,: glass plates or books.).
8. When servicing evaporator part, wear cotton gloves
without fail. it is to prevent wound by sharp fin of
evaporator.
9. Leave a breakage freezing cycle to a heavy service
center. The gas in cycle inside may soil ambient air.
SERVICING
PRECAUTIONS
AIR RECHARGING
IN COMPRESSOR
Test the refrigeration system by connecting it electrically
before refilling operation. This is necessary to ascertain the
function of the motor-compressor
and identify the defects
immediately. If the defects have been found, empty the old
system of eventual R-12 residue by breaking off the end of
the extension piece at its narrow point. (Figure 1)
Replace the filter and any damaged components.
Unsolder
and pull off the piece remaining inside the service tube and
then attach an extension completely with male Hansen and
last, solder it to the same tube again. (Figure 2)
it is necessary to execute the soldering operation with
valve open so that the fumes caused by oil residue can
come out freely without blowholes between two tubes
during heating the point to be soldered.
The extension fitted with the male Hansen is connected to
the female fitting of the vacuum pump tube. (Figure 3)
Air evacuating from the system begins as soon as the
pump starts. The refrigeration system must be kept under
vacuum until the reading on the low-pressure gauge
indicates vacuum (0 absolute, -t atm., -760 mm Hg) in any
case it is advisable to keep the pump running for about
30 minutes. (Figure 4)
POINT TO BEE]
BROKEN
SERVICE TUBEE]
EXTENSION
Figure I
CHARGE TUBEE] FEMALEr
EXTENSION
HANSEN
MALEE]
HANSEN
SOLDERINGE]
POINT
Figure 2
PRE
GAUGE
Figure 3
Figure 4
-3-

Advertisement

loading

Summary of Contents for LG GR-051SF

  • Page 1 SAFETY PRECAUTIONS Please read the followings before servicing your refrigerator. 1. Check if an electric leakage occurs in the set. 6. Prevent water flowing to electric elements in mechanical parts. 2. When servicing current applying parts, unplug prior to servicing. 7.
  • Page 2 In case that a considerable leakage occurs and to stop the Before performing this operation (if the vacuum pump and vacuum pump will be necessary and add a small quantity refilling cylinder are connected), make sure that the valve of Freon to the system, if vacuum should not be obtained placed between the vacuum pump and refilling tube are (pressure gauge can't fall to 1 atmosphere.), start the...
  • Page 3 AIR RECHARGING IN COMPRESSOR Test the refrigeration system by connecting it electrically It is necessary to execute the soldering operation with before refilling operation. This is necessary to ascertain the valve open so that the fumes caused by oil residue can function of the motor-compressor and identify the defects come out freely without blowholes between two tubes...
  • Page 4 In case that a considerable leakage occurs and to stop the Before performing this operation (if the vacuum pump and vacuum pump will be necessary and add a small quantity refilling cylinder are connected), make sure that the valve of Freon to the system, if vacuum should not be obtained placed between the vacuum pump and refilling tube are (pressure gauge can't fall to 1 atmosphere.), start the...
  • Page 5: Specifications

    1. SPECIFICATIONS ITEMS SPECIFICATIONS ITEMS SPECIFICATIONS INSULATION DOOR POLYURETHANE DOOR TYPE 1DOOR CABINET POLYURETHANE NET CAPACITY 46 l EVAPORATOR ROLL BOND TYPE CONDENSER TYPE WALL CONDENSER DIMENSION 443(W)X501(H)X450(D)mm (FLUSH BACK) NET WEIGHT 15 Kg DEFROSTING SYSTEM MANUAL SHELF 1 PIECE TEMPERATURE CONTROL KNOB DIAL...
  • Page 6 3. DISASSEMBLY A. DOOR C. COMPRESSOR AND PTC 1. Loosen 1 screw holding an cover hinge and 3 screws 1. Remove Protector Cover, Power Cord and Lead Wire holding an upper hinge to separate the door body. first. (Figure 11) (Figure 7) 2.
  • Page 7: Circuit Diagram

    2000.03.13 100/70 CIRCUIT DIAGRAM THERMOSTAT YL :YELLOW BK:BLACK Y" BL:BLUE _, i GN(GI_.) GN:GREEN PK:PINK 4N-I BL_ _ __C_IOMPRESSOR P.T.C STARTER THE PLUG TYPE ON CIRCUIT DIAGRAM IS SUBJECT TO CHANGE IN DIFFRENT LOCALTIES. 3854,JD1009E...
  • Page 8: Troubleshooting

    5. TROUBLESHOOTING DEFECT CAUSE REMEDY EFFECT GROUP PARTIALLY Evaporatordosenot frost even An empty refrigerantsystem Leakagemust be eliminated by OR COMPLETELY though motor-compressorruns indicatesa leakage of R_2. T his loss resolderingthe defective point or OUT OF continually. is generallyto be lookedfor at the substitutingthe damaged REFRIGERANT soldering pointsconnectingthe...
  • Page 9 NO COOLING Check if the current The Compressor Replace the Poor contacting point doesn't run. Thermostat. flows at the contacting point of the Thermostat. on the main circuit. Check the components Check if the current Poor contacting point Replace the device. flows at the contacting and broken point of the starting...
  • Page 10 COMPRESSOR AND ANOTHER ELECTRIC COMPONENTS Separate the PTC-STARTER from the Compressor and measure the voltage between M and C of the Compressor. OLP works within 30 sec. in forcible OLP operation Measure minimum starting voltage after checking steps 1-3 above. And measure the pressure balance of the PTC with the interval of more than 5 min.
  • Page 11 First, separate the PTC from the Compressor and check the Poor starting or no voltage between NO 5 and 6 operating of the in the PTC with a multitester Compressor. or Wheatstone Bridge. Separate the OLP from the Compressor check resistance value between two terminals of OLP with Tester.
  • Page 12 6. EXPLODED VIEW NOTE : The shape of parts are subject to change in different localities. -14-...
  • Page 13 7. EXPLODED VIEW & NOTE : The shape of parts are subject to change in different localities. -15-...
  • Page 14 WALMART(WAL) Electrical Specification ITEM GR-051SF BUYER MODEL NAME GR_051SF RATED INPUT(W) 70+15% DEFROST INPUT(W) ENERGY CONSUMPTION(kwh/yr) AMPERE(Amp) 0.84 RATING(V/Hz) 115/60 REFRIGERANT R134a CHARGE(Oz) 1.41 COMPRESSOR NS24LBCM 4TM232NFB P6R8MD CAPACITOR-R 10pF/250VAC CAPACITOR-S...
  • Page 15 DEPOT(HDP) Electrical Specification HOME ITEM GR-051SF GR-131SF GR=151SF BUYER MODEL NAME GR_051SF GR_131SPF GR-151SPF RATED INPUT(W) 70+15% 70+15% 70+15% DEFROST INPUT(W) ENERGY CONSUMPTION(kwh/yr) AMPERE(Amp) 0.84 RATING(V/Hz) 115/60 115/60 115/60 REFRIGERANT R134a R134a R134a CHARGE(Oz) 1.41 2.12 3.35 COMPRESSOR NS24LBCM NS24LBCG NS30LACM 4TM232NFB 4TM232NFB...

This manual is also suitable for:

Gr-131sfGr-151sfGr-131spfGr-151spf