INSTALLATION
INSTRUCTIONS
21
Venfing
requiremenf
Ductwork
Recommended
(10.2 cm)
(10.2 cm)
Use Only for Short
Run Installations
(6.35 cm)
0
I
2
3
4
0
I
2
3
4
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8m)
47 ft. (14.3 m )
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
J
/ @ NOTE
-,,
Deduct 6 fL (1.8 m) for each additional elbow. It is not recommended
to use more than four 90° elbows.
ROUTING AND CONNECTING DUCTWORK
@ NOTE
Follow the guidelines below to maximize drying performance and
reduce lint buildup and condensation in the ductwork.
Ductwork and fittings are NOT included and must be purchased
separately.
• Use4-inch (10.2 cm) diameter rigid or semirigid metal ductwork.
• The exhaust duct run should be as short as possible.
• Useas few elbow joints as possible.
• The male end of each section of exhaust duct must point away from
the dryer.
• Useduct tape on all duct joints.
, Insulate ductwork that runs through unheated areas in order to
reduce condensation and lint buildup on duct surfaces.
• Failure to exhaust the dryer correctly will void the dryer's warranty.
J
CORRECTVENTING
I
INCORRECTVENTING