Craftsman 675 Series Operator's Manual page 10

Hide thumbs Also See for 675 Series:
Table of Contents

Advertisement

Available languages

Available languages

NOTE:Thelogsplitter i sfilledto theproper operating level f romthe
manufacturer withShell T ellus® $2 M 32Hydraulic Fluid. H owever, you
MUSTcheckthefluidlevel b efore operating. If notfilled,proceed withthe
following steps:
Muchof the originalfluid hasbeen drawnintothe cylinderand hoses.
Makecertainto refillthe reservoirto preventdamageto the hydraulic
pump.
3.
Checkthefluid levelusingthedipstick.See Figure8. Do not
overfill.
4.
Replacetheventeddipsticksecurely,tighteningit untilthe topof
the threadsare flush with top of the pipe.
5.
Disconnectthe spark plugand primethe pumpby pullingthe
recoilstarteras faras it will go. Repeatapproximately 10 times.
6.
Reconnectthe sparkplug wireand start the enginefollowingthe
instructionsin the Operationsection.
7.
Use thecontrol handleto engagethewedgeto the farthest
extendedposition.Then retractthe wedge.
8.
Refillthe tank as specifiedon thedipstick.
NOTE: Failureto refillthe tank willvoid the splitter'swarranty.
9.
Extendand retractthewedge 12completecyclesto removeany
air trappedin the system(thesystemis "self-bleeding").
10. Refillthe reservoirwithinthe rangemarkedon the dipstick.
NOTE:Somefluid mayoverflowfrom the vent plugas the system