Water Pressure - LG LFX28979SW Owner's Manual

French door refrigerator
Hide thumbs Also See for LFX28979SW:
Table of Contents

Advertisement

38
MAINTENANCE
Performance
Data Sheet
Models
Number
5231JA2002A-S
Use with
replacement c artridge
5231JA2002A
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below.
The concentration
of the indicated substances in water entering the system was reduced to a concentration
less than or equal to
the permissible
limit for water leaving the system as specified in NSF/ANSI 42.
i System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine
|
1
Taste and Odor and Nominal Particulate Class III.
Capacity: 500 gal (1,892 L)
NSF% reduction req, or
Average
InfluentChallenge
Average Product
Average %
Max, permissibleproduct
Substance
Influent
Concentration, Unitsapplyto each
Water
Reduction
Concentration
row
Concentration
water concentration
NominalParticulateClassI
Particlesize: >0.5 to < 1um
24,333
At least 10,000particles/ml
915
96
_> 85%
Chlorinetaste andodor
1.9
2.0 mg/L + 10%
0.07
96.4
_> 50%
ClassIII
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Application Guidelines/Water
Supply Parameters
Service Flow
0.5 gpm (1.89 Ipm)
Water Pressure
20-125 psi (138-862
kPa)
Water Temperature
36 °F - 100 °F (0.6 °C - 37.8 °C)
WARNING
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or
after the system.
Systems must be installed and operated in accordance with
manufacturer's
recommended
procedures and guidelines.
Warranty: See Warrant, Card for Details.
For a replacement
cartridge or for service
contact your local dealer.
You can also visit our website; www.lg.com
or call 1-877-714-7486.
CAUTION
To reduce the risk of property
damage due to water
leakage:
Read and follow. Use instructions
before installation and
use of this system.
Install on COLD water lines only.
Comply with all state and local plumbing codes.
Install a pressure limiting device and water hammer
arrester for inlet water pressures exceeding 80 psi (552
kPa). Refer to Uniform Plumbing Code, Sections 608.2 and
609.10).
Never install or operate where inlet water pressure may
exceed 125 psi (862 kPa).
Protect filter from freezing. Remove filter in temperatures
below 33°F (0.6°C).
Replace cartridge at specified service interval. Cartridge
MUST be replaced at least every 12 months.
Manufactured
for LG® Electronics by:
CUNO Incorporateda 3M Company 400 Research Parkway
Meriden, CT 06450 U.S.A.
Telephone: 203-237-5541
Fax: 203-238-8701