Customer Responsibilities; Product Specincations - Kenmore 153.324190 Owner's Manual

Potable water heating only not suitable for space heating
Table of Contents

Advertisement

Customer
Responsibilities
Thank You
for purchasing
a Sears water heater.
Properly installed and maintained, it should give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed by Sears contact the local
Sears Service Center or any Sears store. They will arrange for
prompt, quality installation by Sears authorized contractors.
The installation must conform with the instructions in this
manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the latest edition
of the
National Electrical Code. This publication is available from
your local government or public library or electric company
or by writing Underwriters Laboratories, 333 Pfingsten Road,
Northbrook, IL 60062.
Abbreviations
Found
In This Instruction
Manual
U.L.-Underwriters
Laboratories,
333
Pfingsten
Rd.,
Northbrook, IL 60062
National Electrical Code-This publication is available from your
local government or public library or electric company or by
writing to U.L. above.
A.N.S.I.-American National Standards Institute
• Read the "Safety Precautions" section, page 2 of this manual
first and then the entire manual carefully. If you don't follow
the safety rules, the water heater will not operate properly. It
could
cause
DEATH,
SERIOUS
BODILY
INJURY
AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, opera-
tion, and maintenance
of this electric water heater. It also
contains warnings throughout the manual that you must read
and be awareof. All warnings and all instructions are essential
to the proper operation of the water heater and your safety.
Since we cannot put everything on the first few pages, READ
THIS ENTIRE MANUAL BEFORE ATTEMPTING
TO
INSTALL OR OPERATE THE WATER HEATER.
• If after reading this manual you have any questions or do not
understand any portion of the instructions, call Sears Service
Center.
Carefully plan the place where you are going to put the water
heater.
Correct
electrical
wiring
and connections
are very
important
in preventing
death from possible electrical
shock
and fires.
Examine the location to ensure the water heater complies
with the _Facts to Consider About the Location" section.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions
for correct installation proce-
dures. Instructions may be obtained from your local dealer,
wholesaler, public utilities or California Office of the State
Architect, 400 P Street, Sacramento, CA 95814.
Product Specifications
MODEL
NUMBER
153.324190
153.324191
153.324290
153.324291
153.324390
153.324391
153.324490
153.324491
153.324690HT
153.324691HT
153.324792
153.324793
*Wiring size based
electrical code.
TANK
CAPACITY
IN GALLONS
30
40
30
40
40
50
DIMENSIONSININCHES
DIAMETER
HEIGHT
22
29_
24
31_
17½
45_
17½
59½
20
48
19_
56¾
RECOVERY RATE
GAI_. PER HOUR
@ 90°E RISE
20.0
20.0
20.0
20.0
20.0
20.0
ELEMENT
WATTAGE
AT 240 VOLTS
UPPER
LOWER
4500
4500
4500
4500
4500
4500
4500
4500
4500
4500
4500
4500
MAXIMUM
FUSE
MINIMUM
WIRE SIZE*
(GAUGE)
10
10
10
10
10
10
OR CIRCUIT
BREAKER
SIZE(AMPS)
30
30
30
30
30
3O
on standard
60°C copper wire. If distance
from fuse box to water heater is more than 90 feet, refer to your local