Troubleshooting
Guide
Start Up Conditions
CONDENSATION
THERMAL
EXPANSION
Whenever the water heater is filled with cold water, a certain
amount of condensation
will form while the burner is on. A
water heater may appear to be leakingwhen in fact the water is
condensation. This usually happens when:
• When a new water heater is filled with cold water for the
first time.
• When gas burns and water vapor is produced
in water
heaters, particularly high efficiency models where flue tem-
peratures are lower.
• When you use large amounts of hot water in a short time
and the refill water is very cold.
Moisture from the products of combustion
condense on the
cooler tank surfaces and form drops of water which may fall
onto the burner or other hot surfaces to produce a "sizzling" or
"frying" noise.
Excessive condensation
can cause pilot outage due to water run-
ning down the flue tube onto the main burner
and putting
out
the pilot.
Because of the suddenness
and amount
of water, condensation
water may be diagnosed
as a "tank leak". After the water in the
tank
warms
up (about
1-2 hours),
the condition
should
disappear.
Do not assume the water heater is leaking until there has been
enough time for the water in the tank to warm up.
An undersized
water heater will cause more condensation.
The
water
heater
must
be sized
properly
to meet
the family's
demands
for hot water including
dishwashers,
washing machines
and shower heads.
Excessive condensation may be noticed during the winter and
early spring months when incoming water temperatures are at
their lowest.
Good venting is essential for a gas fired water heater to operate
properly as well as to carry away products of combustion and
water vapor.
SMOKEIODOR
It is not uncommon to experience a small amount of smoke and
odor during the initial start-up. This is due to burning offofoil
from metal parts, and will disappear in a short while.
Water sup,ply systems may, because of such events as high line
pressure,
trequent
cut-offs,
the effects of water hammer
among
others, have installed
devices such as pressure reducing
valves,
check valves, back flowpreventers,
etc.-to
control these types of
problems.
When
these devices are not equipped
with an internal
by-pass,
and no other measures are taken, the devices cause the
water system to be closed. As water is heated,
it expands (ther-
mal expansion)
and closed systems do not allow for the expan-
sion of heated water.
The water within the water heater tank expands as it is heated and
increases the pressure of the water system. If the relieving point of
the water heater's temperature-pressure relief valve is reac_ed, the
valve will relieve the excess pressure. The temperature-pressure
relief valve is not intended for the constant relief of thermal
expansion.
This is an unacceptable
condition
and must be
corrected.
It is recommended that any devices installed which could create
a closed system have a by-pass and/or the system have an expan-
sion tank to relieve the pressure built by thermal expansion in
the water system. Expansion tanks are available for ordering
through the Sears Service Center. Contact the local plumbing
inspector, water sul_plier, and/or the Sears Service Center for
assistance in controlling these situations.
Thermal
Expansion Tank Specifications
Model
i Tank Capacity
Dimensions
in Inches [ Pipe Fitting
I
Number
InGallons
i Diameter
-- Length
L OnTank
I
153.331020[
2
8 i_
inches
_, Male
153.331050
5
il_474-inches:
74 Male
/
Expansion Tank Sizing Chart
i Inlet*
Water Heater Capacity
(Gallons)
, Water
g
.
Pressure
30
:
40
[
5050 166782
xpanslon
....
_
4
--...
_
_
Tank
40psl
2
i
2
2
,
5
i
5
Capacity-5Opsi
2
i
2
-_5
i
-5--
Needed
'661bfi
2
_
2
_
5
5
1
3
7@si
1
2
]
2
_
5
"
5
r
5
i 80psi
r
2
5
5
_
5
5
i
i
*Highest
recorded
inlet water pressure in a 24 hour period or
regulated water pressure.
NOTE:
Expansion
tanks
are pre-charged
with
a 40 psi air
charge.
If the inlet water pressure
is higher
than 40 psi, the
expansion
tank's air pressure
must be adjusted
to match
that
pressure, but must not be higher than 80 psi.
22