Installation; Select The Best Location - Goldstar WG8005R Owner's Manual

Hide thumbs Also See for WG8005R:
Table of Contents

Advertisement

Available languages

Available languages

Installation
Size
This room air conditioner is
designed for installation in standard
double-hung windows with actual
opening widths from 22" to 36".
The upper and lower window sash
must open sufficiently to allow a
clear vertical opening of 15" from the
bottom of the upper sash to the
window stool.
15" min
(With frame c urtain)Sill
I
).
Interior wall
18 1/2"rain.
'(Without frame curtain)
Offset
1/2"to 11/4"
&
WARNING:This
product is a WINDOW AIR CONDITIONER.
As such,
a standard single=hung or double=hung window is required for proper
installation. Non=window
installations, including using sleeves, holes
in walls, and other installations are not recommended.
Select the best location
1. To prevent vibration and noise, make sure
the unit is installed securely and firmly
2. Install the unit where the sunlight does
not
I _--------_ Awning
shine directly on the unit.
Cooled air
Heat
3. The outside of the cabinet must extend _
_
radiation
outward for at least 11" and there should _
be no obstacles, such as a fence or wall,/
within 20" from the back of the cabinet
"--_
,
because it will prevent heat radiation of the
o
condenser.
co
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
Fence
• All side louvers of the cabinet must remain exposed to the outside of the
structure.
4. Install the unit a little slanted so the back is slightly lower than the front(about W').
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 30"~60" above the floor level.
Owner's Manual
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wg1005r

Table of Contents