SPECIFICATIONS
Maximum SurgeWatts .................
6,600 watts
Continuous Wattage Capacity ...........
4,000 watts
Power Factor ..............................
1.0
Rated Maximum Continuous AC Load Current:
At 120Volts .......................
33.3Amps
At 240 Volts .......................
16.7Amps
Phase.................................
I-phase
Rated Frequency .......................
60 Hertz
FuelTank Capacity ...................
4 U.S.gallons
ShippingWeight .........................
134 Ibs.
GENERAL
MAINTENANCE
RECOMMENDATIONS
The Owner/Operator
is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis;that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate
a
damaged or defective generator.
Engine
Maintenance
See engine owner's manual for instructions.
_
AUTION!
Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES.RETURN
USED OILTO COLLECTION CENTERS.
Generator
Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with
snow, leavesor any other foreign material.
NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
To Clean
the Generator
• Use a damp cloth to wipe exterior surfaces clean.
• A soft bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
STO RAG E
The generator should be started at least once every seven
claysand allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days,use the following guidelines to prepare it for
storage.
Generator
Storage
• Clean the generator as outlined in "To Clean the
Generator"
• Check that cooling air slots and openings on generator
are open and unobstructed.
_
CAUTION!
Storage covers can be flammable.
Do Not place a storage cover over a hot
generator. Let the unit coot for a sufficient time
before placing the cover on the unit.
Engine Storage
See
engine
owner's
manual for
instructions.
Other
Storage Tips
• To prevent gum from forming in fuel system or on
essential carburetor
parts, add fuel stabilizer into fuel
tank and fill with fresh gasoline. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
• Do Not
store gasoline from one season to another
unless it has been treated as described above.
• Replace fuel container
if it starts to rust. Rust and/or dirt
in fuel can cause problems if it's used with this unit.
• Store in clean and dry area.