Specifications - Generac Portable Products 1575-0 Owner's Manual

3100 watt
Table of Contents

Advertisement

Generac Portable P roducts 3,100 W attGenerator
SPECIFICATIONS
Maximum Surge Watts ...............
3,875 Watts
Continuous Wattage Capacity .........
3,100 Watts
Power Factor ..............................
1.0
Rated Maximum Continuous Load Current
At 120 Volts ......................
25.8 Amps
At 240 Volts ......................
12.9Amps
Phase ................................
I-phase
Rated Frequency ......................
60 Hertz
MAINTENANCE
RECOMMENDATIONS
The Owner/Operator
is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.
Engine
Maintenance
See engine owner's manual for instructions.
_
AUTION!
Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals. Thoroughly wash exposed areas
with soap and water.
KEEPOUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES.RETURN
USED OIL TO COLLECTION CENTERS.
Generator
Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: Do Not use a garden hose to clean the generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air
slots, some of the water will be retained in voids and
cracks of the rotor and stator winding insulation. W ater
and dirt buildup on the generator internal windings will
eventually decrease the insulationresistance of these
windings.
To Clean
the Generator
• Use a clampcloth to wipe exterior surfaces clean.
• Soft, bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator. These openings must be kept clean and
unobstructed.
STORAGE
The unit should be started at least once every seven days
and allowed to run at least 30 minutes. If this cannot be
done and you must store the unit for more than 30 days,
use the following guidelines to prepare it for storage.
Generator
Storage
• Clean the generator as outlined in "To Clean the
Generator" on this page.
• Check that cooling air slots and openings on generator
are open and unobstructed.
_
CAUTION!
Storage covers can be flammable.
Do Not place a storage cover over a hot
generator. Let the unit cool for a sufficient time
before placing the cover on the unit.
Engine Storage
See engine
owner's
manual
for instructions.
Other
Storage
Tips
• Do Not
store gasoline from one season to another.
• Replace your gasoline can if it starts to rust. Rust andlor
dirt in a gasoline can cause problems when you use that
fuel with this unit.
• Store in clean and dry area.
I
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

3100watt