Download Print this page

Philips Lightolier E3 Series Specification page 2

E3 series general duty thermoplastic emergency lighting

Advertisement

G
ENERAL
Ordering Information
Series
6 V Lead Calcium
12 V Lead Calcium
2
E3112 = 12 W
E3225 = 25 W
E3125 = 25 W
E3236 = 36 W
1
E3136 = 36 W
E3250 = 50 W
E3150 = 50 W
12 V Nickel Calcium
6 V Nickel Calcium
E32N25 = 25 W
E31N25 = 25 W
E32N50 = 50 W
E31N50 = 50 W
Accessories (order as a separate item)
SDREMOTE = Infrared Remote Test Device
PCS1 = Polycarbonate Vandal Shield
WG5 = Wire Guard
Note 1) Not available with DL option. 2) Only available with non-diagnostic models. 3) Only available with diagnostic electronic models. 4) Some option combinations
may impact UL listing, consult factory for specifics.
* Lamp included per UL acceptance. ** UL testing restricts using any substitutes for this lamp option.
Electrical Specifications
Non-Diagnostic Models (60 Hz)
6 V Lead Calcium: 0.115 A (120 VAC), 0.050 A (277 VAC)
6 V NiCad: 0.160 A (120 VAC), 0.071 A (277 VAC)
12 V Lead Calcium: 0.126 A (120 VAC), 0.055 A (277 VAC)
12 V NiCad: 0.116 A (120 VAC), 0.051 A (277 VAC)
Optics
Wall mounted 7.5' AFF, 'S9' 6 V 9 W Tungsten Lamps Represented
7.5 ft.
0.3
1.2
0.3
2.4
1.1
2.3
0.2
2.3
1.8
0.4
1.0
0.7
0.6
0.4
0.4
Average initial footcandles at floor = 1.08
Maximum initial footcandles at floor = 3.0
Minimum initial footcandles at floor = 0.3
Maximum to minimum ratio = 10.00
* The optics layout shown is intended to be used as reference only. Standard reflectances used were 80/50/20. Lightolier is not responsible for site specific conditions that
may alter the results.
Philips Lightolier
e: lol.webmaster@philips.com
t: (508) 679-8131
w: www.lightolier.com
E3 Series August 9, 2012
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2012. All rights reserved.
D
T
UTY
HERMOPLASTIC
Housing Color
Lamp Heads
W = White
Blank = No
Lamp Heads
B = Black
2
6 V Tungsten
S6 = 5.4 W
S7 = 7.2 W
S9 = 9 W
12 V Tungsten
S9 = 9 W
S12 = 12.5 W
S18 = 18 W
MR16 LED Lamp Heads*
12 V LED
M7F** = 7 Watt, 35°
1.6
0.9
0.7
0.6
0.9
0.6
1.4
0.6
2.3
0.5
2.6
0.8
0.4
1.5
0.4
2.4
0.5
0.8
0.9
25 ft.
E
# of Heads
Model Designator
Blank = Standard,
Non-Diagnostic Unit
1 = One Lamp
SD2 = Diagnostic
Head
Electronics
2 = Two Lamp
Heads
3 = Three Lamp
Heads
Self-Diagnostics Models (60 Hz)
6 V Lead Calcium: 0.113 A (120 VAC), 0.055 A (277 VAC)
6 V NiCad: 0.157 A (120 VAC), 0.065 A (277 VAC)
12 V Lead Calcium: 0.331 A (120 VAC), 0.146 A (277 VAC)
12 V NiCad: 0.200 A (120 VAC), 0.094 A (277 VAC)
1 FC Average
1.6
.5
1.7
0.7
0.5
2.0
0.7
2.6
0.3
1.9
2.0
0.4
2.2
0.6
1.3
0.7
0.4
0.4
Job Information
E3 Series
L
MERGENCY
Factory Installed Options
A = Ammeter
3
BD = Battery Disconnect Switch
DL = Damp Location Listed
EX = Special Input Transformer (specify voltage &
frequency)
4
F1 = 120 VAC Input Fuse
F2 = 277 VAC Input Fuse
P1 = 120 VAC Power Switch
P2 = 277 VAC Power Switch
T = Self-Testing Diagnostics
TA = Audible Self-Testing Diagnostics
TD = Time Delay, 15 Minutes
V = Voltmeter
3
1.2
0.8
0.7
0.7
0.6
1.1
0.6
1.8
0.6
0.4
2.5
0.4
1.1
0.4
2.0
2.2
0.4
0.6
0.7
Type:
IGHTING
Page 2 of 2
3
3
3
3
3
3
3
3
3
3
2.2
0.8
0.2
0.9
0.3
0.4
0.2
6 ft.