Download Print this page

Craftsman 917.275286 Owner's Manual page 18

Garden tractor 27.0 hp, 48" mower electric start automatic transmission

Advertisement

NOTE: The original equipment battery on
your tractor is maintenance free. Do not
attempt to open or remove caps or covers.
Adding or checking level of electrolyte is
not necessary.
TO CLEAN BATTERY AND TERMINALS
Corrosion and dirt on the battery and
terminals can cause the battery to "leak"
power.
1. Remove terminal guard.
2. Disconnect
BLACK battery cable first
then RED battery cable and remove
battery from tractor.
3. Rinse the battery with plain water and
dry.
4. Clean terminals and battery cable ends
with wire brush until bright.
5. Coat terminals with grease or petro-
leum jelly.
6. Reinstall battery (See "REPLACING
BATTERY" in the SERVICE AND AD-
JUSTMENTS
section of this manual).
TRANSAXLECOOLING
The transmission
fan and cooling fins
should be kept clean to assure proper
cooling.
Do not attempt to clean fan or transmis-
sion while engine is running or while the
transmission
is hot. To prevent possible
damage to seals, do not use high pressure
water or steam to clean transaxle.
• Inspect cooling fan to be sure fan blades
are intact and clean.
• Inspect cooling fins for dirt, grass clip-
pings and other materials.
To prevent
damage to seals, do not use com-
pressed air or high pressure sprayer to
clean cooling fins.
TRANSAXLE
PUMP
FLUID
The transaxle was sealed at the factory and
fluid maintenance
is not required for the life
of the transaxle.
Should the transaxle ever
leak or require servicing, contact a Sears or
other qualified service center.
V-BELTS
CheckV-belts for deterioration and wear after
100 hours of operation and replace if neces-
sary. The belts are not adjustable. Replace
belts if they begin to slip from wear.
ENGINE
LUBRICATION
Only use high quality detergent oil rated with
API service classification SF-SJ. Select the
oil's SAE viscosity grade according to your
expected operating temperature.
18
SAE VISCOSITY
GRADES
30
qo
o
10
20
30
4o
TEMPERATURE
RANGE ANTICIPATED
BEFORE NEXT OIL CHANGE
o_ v_
dlart4 e
Change the oil after every 50 hours of op-
eration or at least once a year if the tractor
is not used for 50 hours in one year.
Check the crankcase oil level before start-
ing the engine and after each eight (8)
hours of operation.
TO CHANGE ENGINE OIL
Determine temperature
range expected
before oil change. All oil must meet API
service classification
SF-SJ.
• Be sure tractor is on level surface.
• Oil will drain more freely when warm.
• Catch oil in a suitable container.
1. Remove oil fill cap/dipstick.
Be careful
not to allow dirt to enter the engine
when changing oil.
2. Install the drain tube onto the fitting.
3. Open drain valve by using a 7/16"
(11 mm) wrench turning counterclock-
wise.
Oil Drain Valve
To Open
To Close
J
Drain
4. After oil has drained completely, close
the drain valve turning clockwise. Use
the 7/16" (1 lmm) wrench to apply
a small amount of torque to keep it
closed. Do not over tighten.
5. Remove the drain tube and store in a
safe place.
6. Refill engine with oil through oil fill dip-
stick tube. Pour slowly. Do not overfill.
For approximate capacity see "PROD-
UCT SPECIFICATIONS"
section of this
manual.
7. Use gauge on oil fill cap/dipstick for
checking level. Insert dipstick into
the tube and rest the oil fill cap on the
tube. Do not thread the cap onto the
tube when taking reading.
Keep oil
at "FULl.:' line on dipstick. Tighten cap
onto the tube securely when finished.

Advertisement