Craftsman 390.269451 Owner's Manual page 3

Submersible utility pump

Advertisement

14.Protect
electrical
cord from sharp
objects,
hot surfaces,
oil, and chemicals.
Avoid kinking
the cord. Replace
or re-
pair damaged
or worn
cords
immediately.
15. Do not touch an operating
motor.
Modern
motors
are de-
signed to operate
at high temperatures.
16. Do not handle
a pump
or pump
motor
with wet hands or
when
standing
on a wet or damp
surface,
or in water.
I_.WARNING]
Risk of electric
shock.
If your
basement
has water
or moisture
on the floor,
do not walk
on wet
area
until
all power
has
been
turned
off.
If shut-off
box is in basement,
call the electric
company
to shut-
off service
to the house,
or call your
local
fire depart-
ment
for
instructions.
Remove
pump
and
repair
or
replace.
Failure
to follow
this
warning
can
result
in
fatal
electrical
shock.
INSTALLATION
[AWARNINGIDo
not
use power
_ord
to lift motor.
Al-
ways
use handle.
NOTICE:
Do not use this pump
in ponds
containing
plants
or fish.
ELECTRICAL
CONNECTIONS
The Pump
has a 3-prong
electric
plug. The third
prong
is
used to ground
the pump
to prevent
possible
fatal shock.
The third
prong
should
never
be removed.
Your electrical
outlet
should
be the 3-prong,
polarized
type with
an inter-
nal ground.
A separate
15 amp GFCI branch
electrical
circuit
is recom-
mended.
DO NOT USE AN EXTENSION
CORD.
Testing for Ground
For your safety, check your outlet
for ground
using a Circuit
Analyzer.
(Figure
A). A Circuit Analyzer
will tell you by a pat-
tern of lights if the power,
neutral,
and ground
wires
are cor-
rectly connected
to your outlet.
It can also be used to check
other
outlets
in your home.
A Circuit
Analyzer
is available
in
the Sears Electrical
Department.
1. Pump
should
be located
and should
rest on level
solid
foundation.
Do not suspend
pump
by means
of discharge
pipe or power
cord.
Keep pump
inlet screen
clear.
2. Thread
outlet
pipe
into
pump
body
carefully
to avoid
stripping
or crossing
threads.
a. To install
with
3/4" garden
hose,
install adapter
pro-
Figure
A
vided with pump.
b. To install with rigid pipe, use plastic pipe. Wrap thread
with Teflon
tape or use Plasto Joint
Stik*. Screw
pipe
into pump
hand
tight +1 - 1-1/2 turns.
NOTICE:
Do not try to disassemble
pump
farther
than re-
moving
inlet screen.
Any evidence
of tampering
will void
warranty.
3. Power
Supply: Pump
is designed
for 115V, 60 Hz opera-
tion and requires
a circuit
of 15 amperes
or more capac-
ity.
It is
supplied
with
a
3-wire
cord
set
with
Face
grounding-type
plug for use in a 3-wire, grounded
outlet.
Plate Screw
3 wire extension
cord, of at least 14 AWG (2mm 2) size is
suggested,
with
larger sizes for runs over 25 ft (7M). For
Figure
B
safety, pump
should always be electrically
grounded
tn a
suitable
electrical
ground
such as a grounded
water
pipe
or a properly
grnunded
metallic
raceway,
or ground
wire
system.
Do not cut off the round
grounding
prong.
[_WARNING]The
pump
motor
is equipped
with
automatic
resetting
thermal
protector
and
may
re-
start
unexpectedly.
ProtectDr
tripping
is indication
of motor
overloading
as a result
of operating
pump
at low
heads
(low
discharge
restriction),
exces-
sively
high
or low
voltage,
inadequate
wiring,
in-
correct
motor
connections,
or a defective
motor
or
pump.
UL Listed
Analyzer
Outlet /
Face Plate
Outlet
Outlet
Box
to Cold
Water
Pipe
6530993
No. 4
Wire
Clamp
Clamp
Metal Water Pipe
Figure
C
Meter
655 0993
*Lake Chemical
Co,
Chicago,
IL