Regency Heatwave P36 Installation Manual

Heat wave duct kit

Advertisement

Quick Links

HEAT WAVE DUCT KIT
KIT # 946-568
P36, P36D, P42, P48, P90, P95, L676S, P33S & HZ54
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to this manual. For assistance or additional information
consult an authorized installer, service agency or the gas
supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapours
and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an author-
ized installer, service agency or the gas supplier.
Tested by: Warnock Hersey
918-225c
Approved for use with Models:
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
www.regency-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
* Do not try to light any appliance
* Do not touch any electrical switch: do not
use any phone in your building.
* Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call
the fi re department.
Manufactured by:
FPI Fireplace Products International Ltd.
6988 Venture St.,
Delta, B.C. Canada, V4G 1H4
11/19/09

Advertisement

Table of Contents
loading

Summary of Contents for Regency Heatwave P36

  • Page 1 fi re department. ized installer, service agency or the gas supplier. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Tested by: Warnock Hersey Manufactured by: FPI Fireplace Products International Ltd. 6988 Venture St., Delta, B.C. Canada, V4G 1H4 11/19/09 918-225c...
  • Page 2: Listings And Code Approvals

    LISTINGS AND CODE GENERAL 3) This kit is tested and safe when installed APPROVALS INFORMATION in accordance with this installation manual. Please read all instructions before starting installation and follow all instructions care- This Kit has been approved for use with Model The Heat Wave Air Duct Kit increases the ef- fully during installation.
  • Page 3: Minimum Framing Clearances

    MINIMUM FRAMING CLEARANCES * Wall studs must be 16" on center for mounting fan housing. * Fan Housing: Maintain a 1/4" (6mm) clearance from fan housing to combustible material. * Wall Registers must be 4"(102mm) from fl oor above or ceiling below. P33 / P36 / P36D / P48 12”...
  • Page 4: Installation

    A) P90 / P95 Model: B) All models: INSTALLATION 1) Remove the knockout plate from the fi re- 1) Determine the location of the air register/fan NOTE: Installation of Heat Wave duct kit should place top and discard. housing assembly. Cut a 5" x 16" (121mm be done prior to drywall installation.
  • Page 5 3) Install the air duct run. The air duct run has a zero clearance to combustibles construc- tion but the fi rst 24" of the pipe from the unit requires insulation (included with kit). Check local codes. Secure the duct to the duct collar on the unit and to the fan housing with 3 screws (per end) and aluminum duct tape (UL 181A-P or equivalent).
  • Page 6: Wiring Diagram

    WIRING DIAGRAM NOTE: The wires (in dotted lines) and wire nuts are supplied by others. Ground Lug Caution: Ensure that the wires do Do not cut the ground terminal off CAUTION: Label all wires prior not touch any hot surfaces and are under any circumstances.
  • Page 7 NOTES Regency Heat Wave Air Duct Kit...
  • Page 8 © FPI Fireplace Products International Ltd. 2009 Printed in Canada...