LG DLE5911W Owner's Manual page 18

Electric and gas dryer
Hide thumbs Also See for DLE5911W:
Table of Contents

Advertisement

Available languages

Available languages

Gas Dryers
NOTE : The gas service to a gas dryer must conform
with the local codes and ordinances or, in the absence
of local codes and ordinances, with the latest edition
of the National Fuel Gas Code ANSI Z223.1/NFPA
54 or the CAN/CGA-B149,
National Gas Installation
Code.
L.P (Liquefied
Petroleum) Gas, 2,500 Btu/f? (93.1
MJ/m3), service
must be supplied
at 10_+ 1.5 in. water
column
pressure.
NOTE : DO NOT connect the dryer to L.P. Gas
Service without converting the gas valve.
L.P. gas conversion:
In U.S.- Conversion
must he made by a qualified
technician.
See gas valve burner base for gas conversion kit part
number.
_-
Conversion must he made by a licensed
technician. Contact your local service branch if you
require further assistance.
The dryer must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping
system at test presure equal to or less than 1/2 psi (3.45
kPa).
NOTE : When connecting to a gas line, an equipment
shutoff valve must he installed within 6 feet (l.8m) of
the dryer. An 1/8 in. N.P.T. pipe plug must be
installed as shown. Refer to Fig
Supply line requirements:
Provide a rigid gas supply line to the dryer location.
/n U.S.- An individual
manual
shutoff valve must be
installed
within
1.8m (6 feet) of the dryer in accordance
with the National
Fuel Gas Code ANSI Z223.1 *.
In Canada-
An individual manual shutoff valve must be
installed in accordance
with the B-149 installation
codes,
CAN/CGA
B-149.1 and B-149.2".
When a rigid pipe is used it should be 112 inch IPS.
When acceptable
to the gas supplier and local codes, 3/8-
inch approved
tubing may be used for lengths under 6. I
m (20 feet). For lengths over 6.1 m (20 feet), larger
tubing should be used. Pipe-joint
compounds
resistant
to
the action of L.P. gas must be used.
To reduce the risk of gas leaks, fire or
explosion:
• The dryer must be connected to the
type of gas as shown on the nameplate
located in the door recess.
• Use a new flexible stainless
steel
connector.
• Use pipe joint compound
insoluble
in
L.P. (Liquefied
Petroleum)
Gas, or
Teflon tape, on all pipe threads.
• Purge air and sediment from gas supply
line before connecting
it to the dryer.
Before tightening
the connection,
purge
remaining air from gas line to dryer
until odor of gas is detected.
This step
is required to prevent a gas valve
contamination.
• Do not use an open flame to check for
gas leaks. Use a non-corrosive
leak
detection fluid.
• Any dis-assembly
requiring the use of
tools must be per[ormed
by an
authorized
qualified service person.
18