Model D4137
2 HP 110V Magnetic Switch
Instruction Sheet
Phone #: (360) 734-3482 • Online Tech Support: tech-support@shopfox.biz • Web: www.shopfox.biz
Figure 1. Model D4137 magnetic
switch.
IMPORTANT: This magnetic switch toggles a motor ON and OFF, and helps provide thermal overload
protection for the motor if the operating temperature gradually increases due to heavy work loads. The
thermal overload relay inside is not designed to cut power in the event of a sudden motor overload or
stall. To help protect a motor from this type of overload, the power supply circuit must be properly
sized for the full-load current rating of the motor.
OPERATION: When pushed, the green ON button on the outside cover of the magnetic switch allows
current to flow to the magnetic coil, which pulls the contactor closed. The main current then passes
through the thermal overload relay to the motor. If the motor begins to overheat, the relay breaks the
magnetic field, which opens the contactor and cuts current to the motor. The red OFF button manually
breaks the magnetic field, which opens the contactor and disconnects the current to the motor.
Electrocution or
fire could occur if
this switch is not
installed or adjust-
ed by a qualified
electrician!
Contactor TECO CU-16
(110V Coil)
COLOR KEY
BLACK
Bk
GREEN
Gn
RED
Rd
YELLOW
Thermal Overload
Relay TECO RHN-10K
(22–30A)
110 Volt
Single-Phase
Power Source
1
3
5
13
L1
L2
L3
NO
TECO
CU-
16
14
2
4
6
T1
T2
NO
T3
TRIP IND.
M
O R
A
TEST
OFF
RESET
97 NO
98 NO
95 NC
96 NC
2
4
6
T1
T2
T3
2 HP 110V Motor
NO
53
Ground
ON
54
NO
Need help?
Do you have a question about the SHOP FOX D4137 and is the answer not in the manual?