Close Backwall, Rigid Conduit Electrical Connections
1. Lift the front of the griddle top only as far as necessary to gain access to the terminal box on the
body's inside rear.
2. Prop the griddle top up securely to prevent it from failing.
Do not lift the griddle top too high, as thermostat and unit terminals may be damaged
beyond repair.
3. Remove the fastener near the bottom of the terminal box and slide the enclosure up to expose
knockouts.
4. Connect griddle's line leads to the supply wires as shown in the applicable wiring diagram. Do
not disturb the griddle wiring.
5. Slide enclosure down and secure with fastener.
6. Lower the griddle top, making sure that it is securely in place.
Since the griddle is not fused, you must connect it to a fused circuit equipped with a
suitable disconnecting means as required by local authorities.
STANDARD VOLTAGES‐208 VOLTS OR 240 VOLTS 50/60 Hz.‐SINGLE OR THREE PHASE 
  
TOTAL  TOTAL 
MODEL 
CONN. 
KW 
NO. 
KW 
PER 
  
  
CONN 
WEG24R 
8.0 
8.0 
WEG36S 
12.0 
12.0 
WEG36D 
16.2 
16.2 
WEG48D 
21.6 
21.6 
WEG60D** 
27.0 
16.2 
  
  
10.8 
WEG72D* 
32.4 
16.2 
  
  
16.2 
*
NOTE: Two separate conduit connections must be made: each connection carries one-half of the
r
ated load.
**
NOTE: Two separate conduit connections must be made: one connection carries 16.2 KW, the other
connection carries 10.8 KW.
480 VOLTS 50/60 Hz.‐THREE PHASE ONLY 
3 PHASE 
LOADING 
KW PER PHASE 
PER CONN.* 
208 VOLT 
X‐Y 
Y‐Z 
X‐Z 
4.0 
0.0 
4.0 
38.5  19.3  19.3  28.9  16.7  16.7  14.4 
4.0 
4.0 
4.0 
33.4  33.4  33.4  28.9  28.9  28.9  14.4  14.4  14.4 
5.4 
5.4 
5.4 
45.0  45.0  45.0  39.0  39.0  39.0  19.5  19.5  19.5 
10.8 
5.4 
5.4 
68.7  68.7  45.2  59.5  59.5  39.0  29.8  29.8  19.5  103.9 
5.4 
5.4 
5.4 
45.0  45.0  45.0  39.0  39.0  39.0  19.5  19.5  19.5 
5.4 
0.0 
5.4 
45.0  26.0  26.0  39.0  22.5  22.5  19.5  11.3  11.3 
5.4 
5.4 
5.4 
45.0  45.0  45.0  39.0  39.0  39.0  19.5  19.5  19.5 
5.4 
5.4 
5.4 
45.0  45.0  45.0  39.0  39.0  39.0  19.5  19.5  19.5 
NOMINAL AMPS PER LINE WIRE CONN.* 
3 PHASE 
240 VOLT 
4
-
-
480 VOLT 
VOLT  VOLT 
8.3 
8.3 
1 PHASE 
208 
240 
38.5 
33.3 
57.7 
50.0 
77.9 
67.5 
90.0 
77.9 
67.5 
51.9 
45.0 
77.9 
67.5 
77.9 
67.5 